20.
Change to the installer directory if necessary and run the upgrade:
./ibrixupgrade -f
The installer upgrades both the management console software and the file serving node
software on the node.
21.
Verify the status of the management console:
/etc/init.d/ibrix_fusionmanager status
The status command confirms whether the correct services are running. Output will be similar
to the following:
Fusion Manager Daemon (pid 18748) running...
Also run the following command, which should report that the console is passive:
<ibrixhome>/bin/ibrix_fm -i
22.
Check /usr/local/ibrix/log/fusionserver.log for errors.
23.
If the upgrade was successful, fail back the node. Run the following command on the node
with the active agile management console:
<ibrixhome>/bin/ibrix_server -f -U -h HOSTNAME
24.
Verify that the agile management console software and the file serving node software are
now upgraded on the two nodes hosting the agile management console:
<ibrixhome>/bin/ibrix_version -l -S
Following is some sample output:
Fusion Manager version: 5.5.XXX
===============================
Segment Servers
===============
HOST_NAME
---------
ib50-86
ib50-87
You can now upgrade any remaining file serving nodes.
Upgrading remaining file serving nodes
Complete the following steps on each file serving node:
1.
Manually fail over the file serving node:
<ibrixhome>/bin/ibrix_server -f -p -h HOSTNAME
The node will be rebooted automatically.
2.
Move the <installer_dir>/ibrix directory used in the previous release installation to
ibrix.old. For example, if you expanded the tarball in /root during the previous IBRIX
installation on this node, the installer is in /root/ibrix.
3.
Expand the distribution tarball or mount the distribution DVD in a directory of your choice.
Expanding the tarball creates a subdirectory named ibrix that contains the installer program.
For example, if you expand the tarball in /root, the installer is in /root/ibrix.
4.
Change to the installer directory if necessary and execute the following command:
./ibrixupgrade -f
The upgrade automatically stops services and restarts them when the process is complete.
5.
When the upgrade is complete, verify that the IBRIX software services are running on the node:
/etc/init.d/ibrix_server status
The output will be similar to the following. If the IAD service is not running on your system,
contact HP Support.
IBRIX Filesystem Drivers loaded
ibrcud is running.. pid 23325
IBRIX IAD Server (pid 23368) running...
168 Cascading Upgrades
FILE_SYSTEM
----------------------
5.5.205(9000_5_5)
5.5.XXX
5.5.205(9000_5_5)
5.5.XXX
IAD/IAS
IAD/FS
OS
-------
-------
---------
5.5.XXX
GNU/Linux
5.5.XXX
GNU/Linux
KERNEL_VERSION
ARCH
--------------
----
2.6.18-128.el5
x86_64
2.6.18-128.el5
x86_64

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ibrix 9320