General Description - GYS Batium 15/12 Manual

Hide thumbs Also See for Batium 15/12:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 7
Translation of the original instructions
Regulations:
• The device complies with European Directive.
• The certificate of compliance is available on our website.
• EAC conformity mark (Eurasian Economic Commission).
• Equipment in compliance with British requirements. The Brit-
ish Declaration of Conformity is available on our website (see
home page).
• Equipment in conformity with Moroccan standards.
• The declaration C‫( م‬CMIM) of conformity is available on our
website (see cover page).
Disposal:
• This product should be disposed of at an appropriate recycling
facility. Do not dispose of in domestic waste.

GENERAL DESCRIPTION

The Batium range is designed to charge all common batteries including lead-acid , electrolyte or gel batteries.
Reference
Voltage
Battery capacity
CONNECTIONS AND GENERAL OPERATIONS
Ensure that the correct sequences are followed.
Precaution: Check the electrolyte level for open batteries. Fill it up if necessary, before starting the charge.
1. Connect the clamps : Red clamp to the battery's (+) and black clamp to the battery's (-).
2. Connect the charger to the mains on a 230 V socket. An indicator
switches on that matches the latest saved data.
3. Select the battery voltage (6, 12, 24 V) according to the recommendations
features on the battery or according to the battery coupling (series or parallel cf
p.44).
Risk of explosion or acid projections if the wrong voltage
is selected (24V for a 12V battery).
4. Select the battery capacity. The Batium automatically determines the char-
ging current.
5. The charge starts automatically. The display indicates the battery's state of charge. (indicators
Step 1 :
Voltage rises
Step 2 :
Voltage regulation (duration : 2h).
Step 3 :
Charge ends (Floating charge).
In the event of a power cut, the BATIUM saves the state of charge (except in « SOS Recovery » mode),
and resumes the charge using the latest settings.
6. When the battery is charged, disconnect the power supply
7. Disconnect the clamps or the battery connectors.
BATIUM 7/12 • 7/24 • 15/12 • 15/24
7 / 12
6 V
12 V
6 V
From 15 Ah to 130 Ah
7 / 24
15 / 12
12 V
24 V
6 V
Voyant allumé
15 / 24
12 V
6 V
12 V
From 35 Ah to 225 Ah
A
(interface diagram p.44) and
To confirm the selec-
tion, do not press any
button for 5 seconds.
État
Permanent
Flashing
Green
EN
24 V
B
and
)
2
1
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents