FORCED CHARGE
If the battery is deeply discharged (very low voltage <2 V), the charge doesnt not start automatically. The charge
1
indicator
does not switch on. The battery voltage indicators
situation, select the voltage and the charging current, then press the battery voltage button
a "forced charge". The indicator
cannot be recovered (<0.5 V (± 0.3)).
« SOS RECOVERY » (BATIUM 15/12 AND 15/24)
When connecting the battery, the SOS Recovery indicator
scharge over a long period, with a start in sulfation.
The « SOS Recovery » mode uses a specific curve to repair the battery over a 24 to 48 hours cycle.
To activate this feature, follow these steps :
1. Disconnect the battery from the vehicle. (OVERVOLTAGE DANGER)
2. Connect the Batium to the battery.
3. Connect the Batium to the mains.
4. Choose the charging voltage.
5. Activate « Sos Recovery » by pressing the button
are switched off).
1
6. The indicator
switches on and blinks when the "Sos Recovery" stops and the normal charge resumes.
7. The green indicator
PROTECTIONS
The Batiums are protected against short-circuits, polarity reversals and vehicle start (they maintain a constant charge
even when the vehicle is started). It has an anti-spark feature which prevents sparks whilst connecting the Gysflash to
the battery. The Batium will not deliver current if there is no battery detected (no voltage in the clamps).

TROUBLESHOOTING

ANOMALIES
The charge indicator 1 is swit-
ched off. The battery voltage
1
indicators blink alternatively
after 1 minute of charging.
The battery capacity indica-
2
tors flash alternatively.
10
BATIUM 7/12 • 7/24 • 15/12 • 15/24
1
switches on once the buttton is released. If no indicator switches on, your battery
2
indicated the charge is over.
The selected voltage does not
match the battery voltage.
The battery cannot be recovered.
The battery is in short circuit or
damaged
A power consumer has been left
on accidentally (e.g. lights).
The charger is used as a power
supply to compensate for the use
of power consumers that are drag-
ging the battery's energy.
The battery capacity (Ah) is higher
than the charger's
The battery voltage does not rise,
the battery is damaged.
A
, and capacity indicator
6
flashes to signal that the battery suffered a deep di-
4
during 5 seconds, until the indicator
CAUSES
B
are switched on. In this
3
during 5 seconds to start
6
switches on (the indicators
SOLUTIONS
- Unplug the device from the mains while
holding the clamps on the battery.
- Reconnect the BATIUM to the mains
supply.
- Select the correct voltage within 5
seconds of reconnecting the product.
Change the battery.
Change the battery.
Switch off the power consumer and
continue/restart the charge
Charger behaves normally but incorrect
use. The indicator that signals the end
of the charge cannot switch on.
The charging time will be abnormally
long. If possible, use a more powerful
charger
Choose the capacity indicated on your
battery.
Change the battery.