D9412G/D7412G | Program Entry Guide | 4.0 RADXPNTS
P ##
Description
Type
4*
Keyswitch Maintained: Program Point Response as 1. Do not connect initiating devices to a
Keyswitch point.
Normal:
Short:
Open:
Program Point Response as 2, the point responds as follows:
Normal:
Open:
Short:
Trouble and Restoral Reports are not sent if
Alarm and Restoral Reports are not sent if
5*
Keyswitch Momentary: Used for area arming and disarming.
programmed 1. Do not connect initiating devices to a Keyswitch point.
N→S→N:
Open:
Trouble and Restoral Reports are not sent if
Open/Close Point:
6*
Local bells are silenced through the command center.
Normal:
Open:
Short:
*
Keyswitch Points. Special rules apply to points used for Keyswitch functions. These special point types do not respond
the same way to the point response entry as Point Types 1, 2, and 3. Responses for keyswitch point types are described in
Section 4.1.1 Point Responses.
Bosch Security Systems | 10/03 | 47775E
The area is disarmed.
When this point changes from normal to open, the area arms.
A short is a trouble when the area is disarmed. A short is an alarm when the area is
armed. When this point changes from shorted to normal or open, it restores.
When this point changes from open to normal, the area arms.
The area is disarmed.
A short is a trouble when the area is disarmed. A short is an alarm when the area is
armed. When this point changes from shorted to normal or open, it restores.
When this point momentarily changes from normal to shorted to normal, it toggles
the armed state of the area.
An open is a trouble while the point is disarmed. An open is an alarm while the
point is armed.
When this point changes from open to normal, it restores.
Used for point arming and disarming.
The point is armed and sends a Point Closing Report. A Point Closing Report is not
sent if Local Armed is Yes.
An open is an alarm when the point is armed. An open is a trouble when the point
is disarmed. Alarm and Restoral Reports are not sent if
The point is disarmed and sends a Point Opening Report. A Point Opening Report
is not sent if
Local Armed
Local While Disarmed
Local While Armed
is Yes.
Point Response
Local Disarmed
is Yes.
Point Response
is Yes.
EN | 79
is Yes.
must be
must be programmed 1.
Local Disarmed
is Yes.

Hide quick links: