Terex GS32MT-101 Operator's Manual page 56

Table of Contents

Advertisement

Operator's Manual
Operating Instructions
Battery and Charger Instructions
Observe and Obey:
Do not use an external charger or booster
battery.
Charge the battery in a well-ventilated area.
Use proper AC input voltage for charging as
indicated on the charger.
Use only a Genie authorized battery and
charger.
To Charge Battery
1
Be sure the batteries are connected before
charging the batteries.
2
Open the battery compartment. The
compartment should remain open for the
entire charging cycle.
Maintenance-free batteries
1
Connect the battery charger to a grounded AC
circuit.
2
The charger will indicate when the battery is
fully charged.
54
GS
-1432m • GS
-1932m • GS
Standard Batteries
1
Remove the battery vent caps and check the
battery acid level. If necessary, add only
enough distilled water to cover the plates. Do
not overfill prior to the charge cycle.
2
Replace the battery vent caps.
3
Connect the battery charger to a grounded AC
circuit.
4
The charger will indicate when the battery is
fully charged.
5
Check the battery acid level when the charging
cycle is complete. Replenish with distilled
water to the bottom of the fill tube. Do not
overfill.
After Each Use
1
Select a safe parking location—firm level
surface, clear of obstruction and traffic.
2
Lower the platform.
3
Turn the key switch to the off position and
remove the key to secure from unauthorized
use.
4
Charge the batteries.
-1932m Lite
First Edition • Third Printing
Part No. 1308591GT