MDA V7
DeltaT
DeltaT (time, signal)
Gradient
Gradient (time, signal,
count)
Integral
Integral (time, signal)
LevelReached
LevelReachedCount
Count
(signal,level)
LowPassFilter_
LowPassFilter (time,
ASCET_lib
signal, filterTime,
startInput)
Maximum
Maximum (signal)
Migrated formula in MDA V8
Delta (master()) + 0*Raw
(signal)
(signal - State_Delay (signal, NoValue
(0), count)) / (Master() - State_Delay
(Master(), 0, count))
Accumulate_Prefix_Integral
(signal)
Accumulate_Prefix_Sum ((State_
Register (signal != level, !0) && (signal =
level)) ? 1 : 0)
Filter_LowPass1 (signal, 1 / (2*PI*-
filterTime))
Accumulate_Prefix_Maximum
(signal)
Comment
0*signal is required for applying the raster
settings based on an input signal.
Time range between the current and the pre-
vious measured value.
Calculates time(k) - time(k-1).
V8.6 assumes the first value as NoValue.
First derivative of the last count samples.
Time range defined by sample parameter
count.
Signals of the type enumeration (VTAB) are
not supported.
Integral of signal since measure start.
Counts how many times a signal value has
been reached.
Time range: From start
Time range: From start
Maximum value of signal since measure start.