Banner SureCross Performance FlexPower DX80G9M2S-P7 Manual page 9

Hide thumbs Also See for SureCross Performance FlexPower DX80G9M2S-P7:
Table of Contents

Advertisement

SureCross Performance FlexPower Gateway
Inputs
Discrete Inputs
Rating: 3 mA max current at 30V dc
Sample Rate: Up to 62.5 milliseconds
Report Rate: On change of state
ON Condition (NPN): Less than 0.7V
OFF Condition (NPN): Greater than 2V or open
Communication
Hardware (RS-485)
Interface: 2-wire half-duplex RS-485
Baud rates: 9.6k, 19.2k (default), or 38.4k
Data format: 8 data bits, no parity, 1 stop bit
Protocol
Modbus RTU
Operating the devices at the maximum operating conditions for extended periods can shorten the life of the device.
Included with Model
The following items ship with the DX80 radios.
• BWA-HW-002: DX80 Access Hardware Kit, containing four PG-7 plastic threaded plugs, four PG-7 nylon gland fittings, four PG-7 hex
nuts, one 1/2-inch NPT plug, and one 1/2-inch nylon gland fitting. (Not included with IP20 DX80...C models)
• BWA-HW-001: Mounting Hardware Kit, containing four M5-0.8 x 25mm SS screws, four M5-0.8 x 16mm SS screws, four M5-0.8mm
SS hex nuts, and four #8-32 x 3/4" SS bolts
• BWA-HW-003: PTFE tape
• BWA-9O2-C (900 MHz) or BWA-2O2-C (2.4 GHz): Antenna, 2 dBd Omni, Rubber Swivel RP-SMA Male. (Not included with Internal
antenna models)
• Quick Start Guide (128185 for DX80 Gateways or 152653 for MultiHop models)
• MQDC1-506: 5-Euro (single ended) straight cable, 2m (Not included with FlexPower devices)
• BWA-HW-011: IP20 Screw Terminal Headers (2 pack) (Included only with the IP20 DX80...C models)
Warnings
Antenna Installations. Install and properly ground a qualified surge suppressor when installing a remote antenna system. Remote antenna
configurations installed without surge suppressors invalidate the manufacturer's warranty. Keep the ground wire as short as possible and make all
ground connections to a single-point ground system to ensure no ground loops are created. No surge suppressor can absorb all lightning strikes; do
not touch the SureCross® device or any equipment connected to the SureCross device during a thunderstorm.
Exporting SureCross Radios. It is our intent to fully comply with all national and regional regulations regarding radio frequency emissions. Custom-
ers who want to re-export this product to a country other than that to which it was sold must ensure the device is approved in the destina-
tion country. A list of approved countries appears in the Radio Certifications section of the product manual. The SureCross wireless products were
P/N 155285_web
Rev. E
Outputs
Discrete Outputs
Update Rate: Up to 62.5 milliseconds
Output State Following Timeout: OFF
ON Condition (NMOS): Less than 0.7V
OFF Condition (NMOS): Open
Discrete Output Rating (12 I/O NMOS)
Less than 100 mA max current at 30V dc
ON-State Saturation: Less than 0.7V at 20 mA
Environmental
Ratings
Rating for DX80 models: IEC IP67; NEMA 6; (See UL
section below for any applicable UL specifications)
Rating for DX80...C models: IEC IP20; NEMA 1
Conditions
Operating Temperature: −40 to +85 °C (Electronics);
−20 to +80 °C (LCD)
Operating Humidity: 95% max. relative (non-condens-
ing)
Radiated Immunity: 10 V/m, 80-2700 MHz
(EN61000-6-2)
Shock and Vibration
IEC 68-2-6 and IEC 68-2-7
Shock: 30g, 11 millisecond half sine wave, 18 shocks
Vibration: 0.5 mm p-p, 10 to 60 Hz