To Close The Outdoor Unit - Daikin ETSHB16P30EF Installer's Reference Manual

Hide thumbs Also See for ETSHB16P30EF:
Table of Contents

Advertisement

7
|
Unit installation

7.2.4 To close the outdoor unit

Installer reference guide
72
1
b
3
c
a
a Transportation stay
b Nut
c Washer
1 Remove the nut (b) and washer (c) from both transportation stays (a).
2 Remove and discard the washers (c) and transportation stays (a).
3 Re-install the nuts (b) of the compressor mounting bolt and tighten to
10.1 N•m of torque.
a
a
a Screw
b Transportation stay
4 Remove the screws (a) (4×) from the transportation stay (b). Put the screws
(a) aside for later use (see To attach the compressor cover piece).
5 Remove and discard the transportation stay (b).
NOTICE
When closing the outdoor unit cover, make sure that the tightening torque does NOT
exceed 4.1 N•m.
1
3
2
2
a
b
a
4
a
EPRA14~18DAV3+W1 + ETSH/X(B)16P30+50EF
b
c
a
Daikin Altherma 3 H HT ECH₂O
4P679467-1 – 2022.02

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents