Daikin ETSHB16P30EF Installer's Reference Manual page 217

Hide thumbs Also See for ETSHB16P30EF:
Table of Contents

Advertisement

EPRA14~18DAV3+W1 + ETSH/X(B)16P30+50EF
Daikin Altherma 3 H HT ECH₂O
4P679467-1 – 2022.02
Priority heater
#
[9.9.D]
[4-01]
Note: In case power consumption control is DISABLED (for all models) the setting
[4‑01] defines whether backup heater and booster heater can operate
simultaneously, or if the booster heater/backup heater has priority over the
backup heater/booster heater.
In case power consumption control is ENABLED, the setting [4‑01] defines the
priority of the electrical heaters depending on applicable limitation.
BBR16
See
"6.6.4  BBR16 power
functionality.
INFORMATION
Restriction: BBR16 settings are only visible when the language of the user interface is
set to Swedish.
NOTICE
2 weeks to change. After you activated BBR16, you only have 2 weeks to change its
settings (BBR16 activation and BBR16 power limit). After 2 weeks, the unit
freezes these settings.
Note: This is different from the permanent power limitation, which is always
changeable.
Code
Power consumption control DISABLED
[4‑08]=0
0 None : Backup heater and booster heater
can operate simultaneously.
1 Booster heater: The booster heater is
prioritised.
2 Backup
prioritised.
Power consumption control ENABLED
[4‑08]=1/2
0 None : Depending on the power limitation
level, the booster heater will be limited first,
before the backup heater is limited.
1 Booster
power limitation level, the backup heater will
be limited first, before the booster heater is
limited.
2 Backup heater: Depending on the power
limitation level, the booster heater will be
limited first, before the backup heater is
limited.
limitation"  [
4
  64] for detailed information about this
10
Configuration
|
Description
heater: The backup heater is
heater: Depending on the
Installer reference guide
217

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents