6
|
Application guidelines
6.4.3 Setup and configuration – storage tank
6.4.4 DHW pump for instant hot water
Installer reference guide
56
▪
When the heat pump produces domestic hot water, it cannot heat up a space. In
case you need domestic hot water and space heating at the same, we
recommend to produce the domestic hot water during the night when there is
lower space heating demand.
▪
For large DHW consumptions, you can heat up the storage tank several times
during the day.
▪
To heat up the storage tank to the desired storage tank temperature, you can
use the following energy sources:
-
Thermodynamic cycle of the heat pump
-
Electrical backup heater (optional)
-
Bivalent heat source, see
▪
For more information about optimizing the energy consumption for producing
domestic hot water, see "10 Configuration" [
Setup
c
a Cold water IN
b Hot water OUT (shower (field supply))
c DHW pump (field supply)
d Recirculation connection (optional)
▪
By connecting a DHW pump, instant hot water can be available at the tap.
▪
The DHW pump and the installation are field supply and the responsibility of the
installer. For the electrical wiring, see
4
pump" [
127].
▪
For installation instructions of the optional recirculation connection, see the
installation manual of the recirculation kit (141554).
Configuration
▪
For more information, see "10 Configuration" [
▪
You can program a schedule to control the DHW pump via the user interface. For
more information, see the user reference guide.
"6.3 Setting up bivalent heat
4
143].
d
"9.3.7 To connect the domestic hot water
4
143].
4
sources" [
48]
a
b
EPRA14~18DAV3+W1 + ETSH/X(B)16P30+50EF
Daikin Altherma 3 H HT ECH₂O
4P679467-1 – 2022.02