Progress PHN1220 Series User Manual page 36

Hide thumbs Also See for PHN1220 Series:
Table of Contents

Advertisement

Available languages

Available languages

36 Progress
Building In
min. 550
20
600
min. 560
Securing the appliance to the
cabinet
Electrical installation
The manufacturer is not
responsible if you do not follow
the safety precautions from the
Safety chapters.
This appliance is supplied without a main
plug and a main cable.
Cable
Cable types applicable for installation or
replacement: H07 RN-F, H05 RN-F, H05
RRF, H05 VV-F, H05 V2V2-F (T90), H05
BB-F.
For the section of the cable refer to the total
power on the rating plate.
Connecting the terminal board
The appliance has a six-pole terminal
board. The jumpers (bridges) are set for
540
21
558
114
19
591
570
598
594
A
B
operation on a 400 V three-phase with a
neutral wire.
1
2
L 1 – 2 – 3 = phase cables
N 4 = neutral cable
= earth cable
If the mains voltage is different, rearrange
the jumpers on the terminal board (refer to
the connection diagram below). Connect
the ground cable to the terminal. After you
connect the supply cable to the terminal
board, attach it with a junction clamp.
1 2 3 4 5
230V 3~
L1
1 2 3 4 5
230V 1~
L1
1 2 3 4 5
400V 2N~
L1
1 2 3 4 5
400V 3N~
L1 L2 L3
1 = 45 mm
2 = 45 mm
3 = 60 mm
4 = 60 mm
= 70 mm
3
4
5
L2
L3
PE
N
PE
L2
N
PE
N
PE

Advertisement

Table of Contents
loading

Table of Contents