GDS 630 CH Installation And Maintenance Manual

Chain slider gate operators

Advertisement

Quick Links

Installation and Maintenance
Manual
Chain Slider Gate Operators
Inbuilt Models:
GDS 630 CH & GDS 630 CH HD
Made in Australia from Australian & quality imported components
A.B.N. 62 059 806 405
July 2014
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 630 CH and is the answer not in the manual?

Questions and answers

Summary of Contents for GDS 630 CH

  • Page 1 Installation and Maintenance Manual Chain Slider Gate Operators Inbuilt Models: GDS 630 CH & GDS 630 CH HD Made in Australia from Australian & quality imported components A.B.N. 62 059 806 405 July 2014...
  • Page 2: Table Of Contents

    CONTENTS Section No: Page Quick start instructions Safety Precautions Wiring Requirements Installation 9-13 Electrical Cabling Mechanical Installation Electrical Connections Plan view layout/ conduit positions CB6 Control Board layout CB-6 Control inputs / mode settings Variable Speed Drive (VSD) Commissioning Control diagrams Manual Release Instructions Maintenance Details Warranty...
  • Page 3: Quick Start Instructions

    C h a i n S l i d e r G a t e O p e r a t o r s GDS 630 CH & GDS 630 CH HD Made in Australia from Australian & quality imported components •...
  • Page 4 • Securely bolt the 2 chain adjuster brackets to the front and back of the gate on the bottom rail and at a height where the chain adjuster rods are level with the bottom teeth of the idler sprockets • Fit the spacer support tubes for the chain to rest on along the length of the gate at approximately 1m spacing’s and at a height where they are approximately 25mm lower than the bottom of the idler sprockets on the chain drive operator...
  • Page 5 • Manually release the drive (via the knurled knob at the back of the gearbox), the chain can now sit on the spacer support tubes and be ran under the idler sprocket, over the drive sprocket and under the other idler sprocket on the chain drive operator •...
  • Page 6 Ensure stops are installed on the gate for the fully closed and fully open positions. Connect required P.E Beams. Adjust Limits to actuate prior to gate end positions. Connect power supply. Turn on Power. Observe that the M1 op and cl limit indicator led`s turn off when the corresponding limit switch is activated.
  • Page 7 Press the opn button located under the dip switches to begin opening cycle. Ensure the direction the gate travels is in accordance with the opening and closing status LED’s, if not reverse two of the motor wires at the inverter terminals.
  • Page 8: Safety Precautions

    AFETY RECAUTIONS WARNING! FAILURE TO FOLLOW THESE SAFETY PRECAUTIONS AND INSTALLATION INSTRUCTIONS COULD RESULT IN INJURY OR DEATH AND OR DAMAGE TO PROPERTY AND EQUIPMENT • Appropriately licensed and competent personnel only should install the automation equipment. • The operators are designed specifically to open and close sliding gates or doors and should not be used for any other purpose.
  • Page 9: Wiring Requirements

    • Keep loose clothing and hands clear of the gate whilst in operation or potentially able to be operated. • The installer should provide all information concerning the use of the automation equipment as well as instructions regarding the manual override and maintenance procedures to the users of the system. IRING EQUIREMENTS •...
  • Page 10: Plan View Layout/ Conduit Positions

    LAN VIEW LAYOUT CONDUIT POSITION FRONT VIEW R.H.S VIEW TOP VIEW OF BASE CHASSIS...
  • Page 11 CB-6 BOARD LAYOUT FOR INVERTER CONTROLS Mode Selection and Adjustment 17. Electric Lock Control Terminals Protection Fuse 18. Terminals for 24vAC Supply for Inverter Input Terminals Control Logic Motor 1 Drive Output Terminals for Inverter 19. Plug In Receiver Antenna Terminals Motor 2 Drive Output Terminals for Inverter With Optional Shield Motor 1 Limit Switch Inputs...
  • Page 12: Control Inputs / Mode Settings

    Control Inputs / Mode Settings Control Inputs The P.E, OPN and STP inputs require a normally closed switch contact and therefore should be shorted to the COM terminal if not used. This is done via bridging links already on the circuit board (bottom left corner) The CLS, OSC and PED inputs require a normally open switch contact and therefore should be left unconnected if not used.
  • Page 13 Position 6 P.E STOPS CLOSE CYCLE OFF - Activating the P.E input while motors are closing causes the motors to reverse. ON - Activating the P.E input while motors are closing causes the motors to stop but not reverse. Position 7 P.E STOPS OPEN CYCLE OFF - Activating the P.E input while motors are opening is ignored by the controller.
  • Page 14: Variable Speed Drive (Vsd)

    (VSD) ARIABLE SPEED DRIVE UNIT DELTA PARAMETER SET-UP FOR 3 WIRE CONTROL (V1.00 14.6.19) Press mode button to get to setting mode, so go to “U”. Press enter to get into parameters, scroll to select parameter group required, press enter to select, then scroll up to get to required parameter number.
  • Page 15: Commissioning

    OMMISSIONING • Check that the limit switches are the correct way around by observing that the M1 op and cl indicator led`s go out when the corresponding limit switch is activated. If they are the wrong way around, swap over the M1 op and cl limit wires. They can be roughly set so they activate approx 500 to 800mm before the gate reaches its end stops.
  • Page 16: Control Diagrams

    ONTROL DIAGRAMS...
  • Page 17: Manual Release Instructions

    ANUAL ELEASE NSTRUCTIONS Place key in door lock, turn clockwise till released and pull door open Turn knurled knob anticlockwise approx. ½ a turn to release Gate can now be opened by hand. To re-engage the clutch, move the gate by hand Into approx.
  • Page 18: Maintenance Details

    5. M AINTENANCE ETAILS WARNING! Failure to maintain equipment may result in injury or death and/or damage to property and equipment Recommended maintenance to be performed on the operator and gate are as follows:- Operator performs over 150 cycles a day each month Operator performs between 100-150 cycles a day every 2 month...
  • Page 19: Warranty

    ARRANTY Gate Drive Systems Australia warrants that the goods manufactured by it shall be free from defect in manufacture for a period of 12 months from the date of invoice. Should any fault occur within that period as a result of faulty workmanship or materials, Gate Drive Systems Australia at its discretion, replace the product at no charge to the Customer except for removal, installation &...

This manual is also suitable for:

630 ch hd

Table of Contents