GDS 4LV Installation And Maintenance Manual

Industrial swing gate operator

Advertisement

Quick Links

Installation and Maintenance Manual
Installation and Maintenance Manual
Installation and Maintenance Manual
Industrial Swing Gate Operator
Industrial Swing Gate Operator
Industrial Swing Gate Operator
Made in Australia from Australian & quality imported components
Made in Australia from Australian & quality imported components
Model: GDS 4LV
(ATA CB-6 controls)
A.B.N. 62 059 806 405
Jan 2016 V1.01
N14870

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GDS 4LV and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GDS GDS 4LV

  • Page 1 Installation and Maintenance Manual Industrial Swing Gate Operator Industrial Swing Gate Operator Industrial Swing Gate Operator Model: GDS 4LV (ATA CB-6 controls) Made in Australia from Australian & quality imported components Made in Australia from Australian & quality imported components A.B.N.
  • Page 2: Table Of Contents

    CONTENTS Section No: Page No: Safety Precautions Specifications Installation Details ctrical Cabling Mechanical Installation ctrical Connections Commissioning CB-6 control board layout Control circuit diagram 10-11 Manual Release Instructions Maintenance Warranty...
  • Page 3: Safety Precautions

    AFETY RECAUTIONS WARNING! FAILURE TO FOLLOW THESE SAFETY PRECAUTIONS AND INSTALLATION INSTRUCTIONS COULD RESULT IN INJURY OR DEATH AND OR DAMAGE TO PROPERTY AND EQUIPMENT Appropriately licensed and competent personnel only should install the automation equipment. • The operators are designed specifically to open and close sliding gates or doors and should not be used for any •...
  • Page 4: Specifications

    PECIFICATIONS (subject to change without notice) (subject to change without notice) 41kgs (including arms) EIGHT IRING REQUIREMENTS 24v 120w 240v on Control Box side OTOR 100% 2 – 2.5mm min. wires to operator to operator for motor UTY CYCLE 8-12 sec/90 3 –...
  • Page 5: Mechanical Installation

    ECHANICAL NSTALLATION • Firstly determine which gate rail the operator arm is to be mounted to. Firstly determine which gate rail the operator arm is to be mounted to. • Run a level from the top of the gate rail across to where the operator is Run a level from the top of the gate rail across to where the operator is to be installed onto either wall or post.
  • Page 6: Electrical Connections

    LECTRICAL ONNECTIONS Operators:- • 2 x 2.5mm² min wires required for each extra low voltage motor, connected into M1, M2 DIN rail terminals. • 3 x 0.5mm² min wires required for limit switch connections, connected into M1, M2 Limit DIN rail terminals. ONNECTION TO ONTROL OARD...
  • Page 7 ELECTION Using the mode selection dip-switches select the desired operating modes. Note the times associated with the parameters marked with an * can be changed. The auto-close times can be changed using the procedure in the following section. See the detailed installation manual for details on how to change the other parameters. Synchronising Delay OSITION OFF - No delay...
  • Page 8: Commissioning

    ETTING CYCLE TIMERS AND AUTO CLOSE TIMES The control board has pre-set cycle times which are used to set the maximum time the controller will drive the motors in the open and closed directions. The pre-programmed time for the open and close cycle timer’s is 60 seconds.
  • Page 12: Manual Release Instructions

    ANUAL ELEASE ELEASE NSTRU CTIONS • Turn power off to the control box and isolate. Using key to open side door on gate operator cover, Turn power off to the control box and isolate. Using key to open side door on gate operator cover, Turn power off to the control box and isolate.
  • Page 13: Maintenance

    AINTENANCE ETAILS ETAILS WARNING! WARNING! Failure to maintain equipment may result in injury or death and/or damage to Failure to maintain equipment may result in injury or death and/or damage to property and equipment property and equipment Recommended maintenance to be performed on the operator and gate are as follows: Recommended maintenance to be performed on the operator and gate are as follows: - Operator performs over 150 cycles a day Operator performs over 150 cycles a day...
  • Page 14: Warranty

    ARRANTY Gate Drive Systems Australia warrants that the goods manufactured by it shall be free from defect in manufacture for a period of 12 months from the date of invoice. Should any fault occur within that period as a result of faulty workmanship or materials, Gate Drive Systems Australia at its discretion, replace the product at no charge to the Customer except for installation &...

Table of Contents