Swing Gate Operators
Models: GDS 4,6,7
Made in Australia from Australian & quality imported components
(Delta VSD)
10 Bennet Ave Melrose Park SA 5039
8374 3466
March 2020 V 2 .00

Advertisement

Table of Contents
loading

Summary of Contents for GDS GDS 4

  • Page 1 Installation and Maintenance Manual Swing Gate Operators Models: GDS 4,6,7 Made in Australia from Australian & quality imported components (Delta VSD) 10 Bennet Ave Melrose Park SA 5039 8374 3466 March 2020 V 2 .00...
  • Page 2: Table Of Contents

    CONTENTS Section no: page no: Safety Precautions Specifications Installation Electrical Cabling & Mechanical Installation Electrical Connections Mode Selection Variable Speed Drive, precautions for safe use and alternative power supply *refer to Teco L510S quick start guide for parameter lists and settings. Commissioning CB-6 control board layout Schematic wiring diagram...
  • Page 3: Safety Precautions

    AFETY RECAUTIONS WARNING! FAILURE TO FOLLOW THESE SAFETY PRECAUTIONS AND INSTALLATION INSTRUCTIONS COULD RESULT IN INJURY OR DEATH AND OR DAMAGE TO PROPERTY AND EQUIPMENT • Appropriately licensed and competent personnel only should install the automation equipment.  The operators are designed specifically to open and close sliding gates or doors and should not be used for any other purpose.
  • Page 4: Specifications

    10-13 sec/90 PEED DJUSTABLE DJUSTABLE 38 kgs GDS 6 = 61 kgs GDS 7 = 80.00 kgs EIGHT OF OPERATOR NOT INCLUDING ARMS WIRING AND SUPPLY REQUIREMENTS:  240vac single phase on the Control Box side.  1 x 3 core plus earth 1.5mm 3 phase shielded motor cable to each operator.
  • Page 5: Installation

    ECHANICAL NSTALLATION • Firstly, determine which gate rail the operator arm is to be mounted to. • Run a level from the top of the gate rail across to where the operator is to be installed onto either wall or post. •...
  • Page 6: Electrical Connections

    LECTRICAL ONNECTIONS Operators:  Connect the 3 phase motor wires to the motor terminals plus earth and cable shield to the earth terminal. The motor is connected in Delta configuration and the motor links have been set for this connection at the factory. The cable shield has to be connected to earth at both ends.
  • Page 7: Mode Selection

    ELECTION Using the mode selection dip-switches select the desired operating modes. Note the times associated with the parameters marked with an * can be changed. The auto-close times can be changed using the procedure in the following section. See the detailed installation manual for details on how to change the other parameters. Synchronising Delay OSITION OFF -...
  • Page 8 Setting Cycle Timers & Auto Close Times The control board has pre-set cycle times which are used to set the maximum time the controller will drive the motors in the open and closed directions. The pre-programmed time for the open and close cycle timer’s is 60 seconds. The control board also has a pre-set pedestrian access time of 5 seconds which is intended to open the motor connected to M1 output only part way.
  • Page 9 DELTA PARAMETER SET-UP FOR 3 WIRE CONTROL (V1.00 14.6.19) Press mode button to get to setting mode, so go to “U”. Press enter to get into parameters, scroll to select parameter group required, press enter to select, then scroll up to get to required parameter number. Press enter to select. Scroll up or down to select new value, then press enter to enter new value.
  • Page 10: Commissioning

    OMMISSIONING  Position the gate so it is half way, tighten manual release knob to the point where the gate will just start to be driven but the clutch will slip if the gate accidentally hits the gate stop too hard while setting up the limits. Power up board and with gate in the half way position, press transmitter or manual control switch so operator ...
  • Page 11: Control Board Layout

    OMMISSIONING...
  • Page 12: Schematic Wiring Diagram

    DELTA VDF-EL ATA CB-6 Gate Drive Systems Australia ATA CB-6 DELTA VDF-EL DELTA VDF-EL Gate Drive Systems Australia...
  • Page 13: Manual Release Instruction

    Manual Release Instructions  Turn power off to the control box and isolate. Using key to open side door on gate operator cover,  Turn knurled disc anticlockwise for arm to be released from gearbox.  If a magnetic lock is fitted, turn off the power to the control box. ...
  • Page 14: Maintenance Details

    Maintenance Details WARNING! Failure to maintain equipment may result in injury or death and/or damage to property and equipment Recommended maintenance to be performed on the operator and gate are as follows:- Operator performs over 150 cycles a day each month Operator performs between 100-150 cycles a day every 2 month Operator performs between 50-99 cycles a day...
  • Page 15: Warranty

    Nice Australia Home Automation Pty Ltd Warranty Terms Nice Australia warrants that, goods manufactured by it, bearing the GDS brand, shall be free from defect in manufacture for a period of 12 months from the date of invoice. Should any fault occur within that period, as a result, of faulty workmanship or materials, Nice Australia will at its discretion, replace the product at no charge to the Customer except for removal, installation &...