GDS 450 W Installation And Maintenance Manual

Sliding gate operator

Advertisement

Installation and Maintenance Manual
Sliding Gate Operators
Inbuilt Models: GDS 450, 630 W Range
Made in Australia from Australian & quality imported components
A.B.N. 62 059 806 405
October 2013
N14870

Advertisement

Table of Contents
loading

Summary of Contents for GDS GDS 450 W

  • Page 1 Installation and Maintenance Manual Sliding Gate Operators Inbuilt Models: GDS 450, 630 W Range Made in Australia from Australian & quality imported components A.B.N. 62 059 806 405 October 2013 N14870...
  • Page 2: Abbreviated Installation Instructions

    (For those who don't have time!) S l i d i n g G a t e O p e r a t o r s GDS 450, 630 W Range PLEASE NOTE – THE LIMIT SWITCHES WITH THIS RANGE OF OPERATORS ARE ONLY USED...
  • Page 3 To commission the gate, move the gate approximately half way and tighten the knurled wheel (Clockwise) engaging the clutch assembly enough that it will drive the gate but will slip if it accidentally hits its mechanical stop hard during set up. Make sure at end of set up that the clutch is tightened up firm.
  • Page 4: Table Of Contents

    CONTENTS Section numbers page numbers Abbreviated Installation Instructions Safety Precautions Product description and operation Installation details 6-13 Mechanical Installation Wiring requirements Plan view of operator installation for conduit entry points CB6 Control Board CB6 inputs, outputs and settings Variable Speed Drive Unit Commissioning Inverter parameter list Using inverter monitoring function parameters for fault finding...
  • Page 5: Safety Precautions

    1. S AFETY RECAUTIONS WARNING! FAILURE TO FOLLOW THESE SAFETY PRECAUTIONS AND INSTALLATION INSTRUCTIONS COULD RESULT IN INJURY OR DEATH AND OR DAMAGE TO PROPERTY AND EQUIPMENT Appropriately licensed and competent personnel only should install the automation equipment. • The operators are designed specifically to open and close sliding gates or doors and should not be used for any •...
  • Page 6: Product Description And Operation

    PERATION This operator has been developed in order to make installation, commissioning and gate operation as simple and hassle free as possible without detracting from the quality that has always been the trademark of the GDS range of operators. Apart from the upgrade of inverter control to the Prostar unit and cabinet style enclosure with the option of...
  • Page 7: Wiring Requirements

    • mounted. The following diagrams will provide measurements for the positioning of conduits and the appropriate position for mounting the operator whether a GDS 450 W or a GDS 630 W. Electrical Connections • Connect a non earth leakage protected 10A 240v supply to Din Rail terminals labelled A & N, Connect earth to the earth Din Rail terminal.
  • Page 8 CONTROL BOARD LAYOUT FOR INVERTER CONTROLS Mode Selection and Adjustment 17. Electric Lock Control Terminals Protection Fuse 18. Terminals for 24vAC Supply for Inverter Input Terminals Control Logic 19. Plug In Receiver Antenna Terminals Motor 1 Drive Output Terminals for Inverter Motor 2 Drive Output Terminals for Inverter With Optional Shield Motor 1 Limit Switch Inputs...
  • Page 9 Control Inputs The P.E, OPN and STP inputs require a normally closed switch contact and therefore should be shorted to the COM terminal if not used. This is done via bridging links already on the circuit board (bottom left corner) The CLS, OSC and PED inputs require a normally open switch contact and therefore should be left unconnected if not used.
  • Page 10 Position 5 M 2 OUTPUTS STATUS OFF - The M2 output controls second motor ON - The M2 output controls status lights Position 6 P.E STOPS CLOSE CYCLE OFF - Activating the P.E input while motors are closing causes the motors to reverse. ON - Activating the P.E input while motors are closing causes the motors to stop but not reverse.
  • Page 11: Variable Speed Drive Unit

    Commissioning Position the gate halfway and tighten clutch (knurled knob on gearbox) just firm enough to drive the gate but still • allowing it to slip if the slow down switches aren’t adjusted correctly and the gate hits the mechanical stops at full speed.
  • Page 12 Proflex PR600 Inverter parameter list for Wholesale Operator Parameter list number Definition Setting P0.01 Keypad up/down button frequency control P0.06 Upper limit frequency P0.03 Opening speed 60-sliders 50-swings P0.04 Running command via terminals P0.09 Max output voltage P0.14 Acceleration time P0.15 Deceleration time P2.28...
  • Page 13 Using inverter monitoring parameters for monitoring and fault finding • From the main screen “0.00” press the PRG button once to get to the parameter menu screen “D-00”. • Use >> button to select required digit on screen to change then scroll that digit up or down with the up/down ↕ button.
  • Page 14: Schematic Wiring Diagram Of Controls

    CHEMATIC IRING IAGRAM...
  • Page 15: Manual Release Operation

    ANUAL ELEASE NSTRUCTIONS Place key in door lock turn clockwise till released then pull open door. Turn knurled knob anticlockwise approx. 1/2 a turn to release clutch. Gate can now be opened by hand. To re-engage the clutch move the gate by hand into approx the half way position and turn the the knurled knob clockwise until it is very tight.
  • Page 16: Maintenance Schedule

    AI NTENANCE ETAILS WARNING! Failure to maintain equipment may result in injury or death and/or damage to property and equipment Recommended maintenance to be performed on the operator and gate are as follows:- Operator performs over 150 cycles a day each month Operator performs between 100-150 cycles a day every 2 month...
  • Page 17: Warranty

    ARRANTY Gate Drive Systems Australia warrants that the goods manufactured by it shall be free from defect in manufacture for a period of 12 months from the date of invoice. Should any fault occur within that period as a result of faulty workmanship or materials, Gate Drive Systems Australia will at its discretion, replace the product at no charge to the Customer except for installation and freight.