Mechanical damages
Damage caused by liquids or media
Natural loss
Not correct installation
6 Detailed specifications
Output sensitivity ( FS )
Maximum capacity ( Emax )
Max.number of load cell
intervals
Ratio of min. LC verification
interval
Combined Error
Minimum dead load
Safe overload
Ultimate overload
Zero balance
Excitation, recommended
voltage
Excitation maximum
Input resistance
Output resistance
Insulation resistance
Compensated temperature
Operating temperature
Storage temperature
7 Wiring
Shielded, 4 conductor cable. Cable diameter: Ø5mm. Standard cable length: 20m.
Shield not connected to element
4-wire diagram
4
mV/V
1.5 ± 0.002
t
10, 20, 30, 40, 50, 100
n
LC
2000
Y = E
/
max
5000
v
min
≤± 0.03
%FS
Of E
0%
max
of E
150 %
max
of E
300 %
max
of FS
< ± 1.0 %
V
5 ~ 12
V
18
Ω
700 ± 7
Ω
703 ± 4
MΩ
≥5000 ( at 50VDC )
°C
-10 ~+40
°C
-35 ~ +65
°C
-40 ~ +70
Input(+)
red
Output(-)
white
Input (-)
black
Output(+)
green
CD P2-BA-e-1810