Control the measuring cells to deformations and cracks.
Measuring cells with 4-Conductor cable will change their characteristic value when
shortened or extended the cable length.
5 Warranty
The warranty expires at:
Disregard of the specifications of the operating manual
Modification or opening the measuring cell
Overload
Mechanical damages
Damage caused by liquids or media
Natural loss
Not correct installation
6 Detailed specifications
Output sensitivity ( FS )
Maximum capacity ( Emax )
Max.number of load cell
intervals
Ratio of min. LC verification
interval
Combined Error
Minimum dead load
Safe overload
Ultimate overload
Zero balance
Excitation, recommended
voltage
Excitation maximum
Input resistance
Output resistance
Insulation resistance
Compensated temperature
Operating temperature
Storage temperature
Recommended torque on
fixation bolts
4
CP P9-BA-e-1911
mV/V
kg
10, 20, 50, 100, 200,
300, 400,500
nLC
Y = Emax
10000
/ vmin
%FS
Of Emax
of Emax
of Emax
of FS
V
V
(10kg, 20kg, 50kg)
Ω
380 ± 15
Ω
MΩ
°C
°C
°C
Nm
2.0 ± 0.2
3000
20000
≤± 0.0230
0%
150 %
300 %
< ± 2.0 %
5 ~ 12
18
(100kg, 200kg,
300kg, 400kg, 500kg)
350 ± 10
≥5000 ( at 50VDC )
-10 ~+40
-35 ~+65
-40 ~ +70
M6: 10
10, 20, 50
4000
4000
350 ± 3.5
M8:25