5 Warranty

The warranty expires at:
 Disregard of the specifications of the operating manual
 Modification or opening the measuring cell
 Overload
 Mechanical damages
 Damage caused by liquids or media
 Natural loss
 Not correct installation

6 Detailed specifications

Output sensitivity ( FS )
Maximum capacity ( Emax )
Max.number of
intervals
Ratio of min. LC verification
interval
Combined Error
Minimum dead load
Safe overload
Ultimate overload
Zero balance
Excitation,
recommended
voltage
Input resistance
Output resistance
Insulation resistance
Compensated temperature
Operating temperature
7 Wiring
Shielded, 4 conductor cable. Cable Ø6mm. Shield not connected to element
Standard cable length 60kg...1000kg: 3m.
Standard cable length 2000kg: 6m
4-wire diagram
4
mV/V
kg
nLC
load
cell
Y = Emax
/ vmin
%FS
Of Emax
of Emax
of Emax
of FS
V
Ω
Ω
°C
°C
Input(+)
Pink
Output(-)
White
Input (-)
Gray
Output(+)
Brown
1.0 ± 0.01
1.75 ± 0.2
60, 130
250
3000
10000
≤± 0.05
0%
150 %
200 %
< ± 2.0 %
10 ~ 15
1260 ±
100
1020 ±
≥5000 ( at 50VDC )
0.5
-10 ~+40
-50 ~ +70
CR P1-BA-e-1910.docx
2.0 ± 0.1
500, 1000,
2000
1100 ± 100
1025 ± 25

Advertisement