RSD-CFA-CN and RSD-FC-CN.3km
Installation
The RSD-CFA-CN and the RSD-FC-CN.3km must not be exposed to the environ-
ment. Provide a separate enclosure with a protection factor of at least IP54. These
modules must be installed in such a way that protection factor IP20 is guaranteed.
Repair
These modules are not field-repairable. Any attempt to open these modules will
void the warranty and IS certification. If repair is necessary, return these modules
to the factory.
ESD
Protect the system against electrostatic charge. Post a sign near these modules:
„Attention! Avoid electrostatic charge".
Ambient Temperature
The ambient temperature of these modules (-20 °C...+70 °C) has to be conside-
red, especially when the modules are mounted in a cabinet where the internal
temperature is increased by the power dissipation of the modules itself.
European Union Directive Compliance
If this product has the CE mark it is approved for installation within the European
Union and EEA regions. It has been designed and tested to meet the following di-
rectives:
EMC Directive
This product is tested to meet Council Directive 89/336/EEC Electromagnetic
Compatibility (EMC) and the following standards, in whole or part, documented in
a technical construction file:
- EN 50081-2; EMC-Generic Emission Standard, Part 2 - Industrial Enviroment.
- EN 50082-2; EMC-Generic Immunity Standard, Part 2 - Industrial Enviroment.
This product is intended for use in an industrial enviroment.
Low Voltage Directive
This product is tested to meet Council Directive 73/23/EEC Low Voltage, by app-
lying the safety requirements of EN 61131-2 Programmable Controllers, Part 2 -
Equipment Requirements and Tests.
For specific informations required by EN 61131-2, see the appropriate sections in
this publication.
This equipment is classified as open equipment and must be mounted in an enclo-
sure during operation to provide safety protection.
Subject to reasonable modifications due to technical advances
Pepperl+Fuchs Group·Tel.: Germany (6 21) 776-11 11·USA (3 30) 4 25 35 55·Singapore 7 79 90 91·Internet http://www.pepperl-fuchs.com
Instruction Manual
Copyright Pepperl+Fuchs, Printed in Germany
RSD-CFA-CN and RSD-FC-CN.3km
The Copper/Fiber-Adapter RSD-CFA-CN works in conjunction with the Fiber-
Coupler RSD-FC-CN.3km.
Mounting
The RSD-CFA-CN and the RSD-FC-CN.3km do not need a separate Terminal
Base. The Copper/Fiber-Adapter provides the coupling to the ControlNet coax ca-
ble, the Fiber-Coupler realizeses the connection to the fiber optic cable. Both de-
vices are connected via a plug, which is located at the right hand side of the RSD-
CFA-CN and the left hand side of the RSD-FC-CN.3km. Before both devices are
mounted the cover plug on both units must be removed. Only remove the cover
plug when mounting. The mounting and the connection of the devices is shown
infigure 1.
Figure 1
A maximum of 2 RSD-FC-CN.3km are allowed to be connected to one
Subject to reasonable modifications due to technical advances
Pepperl+Fuchs Group·Tel.: Germany (6 21) 776-11 11·USA (3 30) 4 25 35 55·Singapore 7 79 90 91·Internet http://www.pepperl-fuchs.com
Instruction Manual
Copyright Pepperl+Fuchs, Printed in Germany
Need help?
Do you have a question about the RSD-CFA-CN and is the answer not in the manual?