Daikin ERGA06EAV3H Installer's Reference Manual page 290

Hide thumbs Also See for ERGA06EAV3H:
Table of Contents

Advertisement

6/12
Field settings table
Breadcrumb
Field code
Setting name
9.2.1
[E-05]
Domestic hot water
[E-06]
[E-07]
9.2.2
[D-02]
DHW pump
9.2.4
[D-07]
Solar
└─ Back up heater
9.3.1
[E-03]
BUH type
9.3.2
[5-0D]
Voltage
9.3.3
[4-0A]
Configuration
9.3.4
[6-03]
Capacity step 1
9.3.5
[6-04]
Additional capacity step 2
9.3.6
[5-00]
Equilibrium: Deactivate backup heater (or external backup heat source in case of a
bivalent system) above the equilibrium temperature for space heating?
9.3.7
[5-01]
Equilibrium temperature
9.3.8
[4-00]
Operation
└─ Booster heater
9.4.1
[6-02]
Capacity
9.4.3
[8-03]
BSH eco timer
9.4.4
[4-03]
Operation
└─ Emergency
9.5.1
[4-06]
Emergency
9.5.2
[7-06]
Compressor forced OFF
└─ Balancing
9.6.1
[5-02]
Space heating priority
9.6.2
[5-03]
Priority temperature
9.6.3
[5-04]
Offset BSH setpoint
9.6.4
[8-02]
Anti-recycle timer
9.6.5
[8-00]
Minimum running timer
9.6.6
[8-01]
Maximum running timer
9.6.7
[8-04]
Additional timer
Installer settings
9.7
[4-04]
Water pipe freeze prevention
└─ Benefit kWh power supply
9.8.2
[D-00]
Allow heater
9.8.3
[D-05]
Allow pump
9.8.4
[D-01]
Benefit kWh power supply
9.8.6
Allow electric heaters
9.8.7
Enable Room buffering
9.8.8
Limit setting kW
└─ Power consumption control
9.9.1
[4-08]
Power consumption control
9.9.2
[4-09]
Type
4P681207-1 - 2021.12
Range, step
Default value
R/O
HPSU 'Integrated'
R/W
0: No DHW pump
1: Instant hot water
2: Disinfection
3: Circulation
4: Circulation and disinfection
R/W
0: No
1: Yes (DHW)
2: Yes (DHW + SH)
R/O
0: no heater (*7)
(*4,*5,*6)
2: 3V (*4)
R/W (*7)
3: 6V (*5)
4: 9W (*6)
R/O
0: 230V, 1~ (*4, *5, *7)
2: 400V, 3~ (*6)
R/W (*5,
0: 1 (*4, *7)
*6, *7)
1: 1/1+2 (*5, *6)
R/O (*4)
2: 1/2
3: 1/2 + 1/1+2 in emergency
R/W
0~10kW, step: 0,2kW
0kW
2kW (*5)
3kW (*4, *6, *7)
R/W (*5,
0~10kW, step: 0,2kW
*6)
0kW (*4)
R/O (*4,
3kW (*7)
*7)
4kW (*5)
6kW (*6)
R/W
0: No
1: Yes
R/W
-15~35°C, step: 1°C
0°C
R/W
0: Restricted
1: Allowed
2: Only DHW
R/W
0~10kW, step: 0,2kW
0kW
R/W
20~95 min, step: 5 min
50 min
R/W
0: Restricted
1: Allowed
2: Overlap
3: Compressor off
4: Legionella only
R/W
0: Manual
1: Automatic
2: Auto red SH/ DHW ON
3: Auto red SH/ DHW OFF
4: Auto normal SH/ DHW OFF
R/W
0: Disabled
1: Enabled
R/W
0: Disabled
1: Enabled
R/W
-15~35°C, step: 1°C
0°C
R/W
0~20°C, step: 1°C
10°C
R/W
0~10 hour, step: 0,5 hour
0,5 hour
R/W
0~20 min, step 1 min
1 min
R/W
5~95 min, step: 5 min
30 min
R/W
0~95 min, step: 5 min
95 min
R/W
0: Continuous pump operation
1: Non continuous pump operation
2: OFF
R/W
0: None
1: BSH only
2: BUH only
3: All
R/W
0: No
1: Yes
R/W
0: No
1: Open
2: Closed
3: Smart Grid
R/W
0: No
1: Yes
R/W
0: No
1: Yes
R/W
0~20 kW, step: 0,5 kW
2 kW
R/W
0: No
1: Continuous
2: Inputs
3: Current Sensor
R/W
0: Amp
1: kW
(*6) *EKECBUA3V*_(*7) *EKECBUA6V*_(*8) *EKECBUA9W*_(*9) BUH less_
Installer setting at variance with
default value
Date
Value
(*1) 300 Tank_(*2) 500 Tank_
(*3) *X*_(*4) *H*_(*5) *B*_
(*10) 04P_(*11) 08P