Daikin ERGA06EAV3H Installer's Reference Manual page 139

Hide thumbs Also See for ERGA06EAV3H:
Table of Contents

Advertisement

ERGA04~08EAV3+V3A+V37 + EHSH/X(B)04+08P30+50EF
Daikin Altherma 3 R ECH₂O
4P678716-1 – 2022.01
[9.8.4]=3 (Benefit kWh power supply = Smart grid)
[9.8.5] Smart grid operation mode
[9.8.6] Allow electrical heaters
[9.8.7] Enable room buffering
[9.8.8] Limit setting kW
The wiring of the Smart Grid in case of high voltage contacts is as follows:
X1 M
2
23
A1
A2
N
L
N
L
K1A
2
1
a
STEP 3
STEP 1 Smart Grid relay kit installation
STEP 2 Low voltage connections
STEP 3 High voltage connections
1
High voltage Smart Grid contact 1
2
High voltage Smart Grid contact 2
a, b Coil sides of relays
c, d Contact sides of relays
e Jumper (factory-mounted). If you also connect a safety thermostat (Q4L), replace
the jumper with the safety thermostat wires.
f Smart Grid pulse meter
1 Install the switch box metal insert.
1
2 Loosen the cables connected to the terminal of the Smart Grid relay kit
(EKRELSG) and remove the terminal.
X 5M
1
25
24
25
4
3
6
5
A1
A2
K2A
K1A
K2A
b
c
d
STEP 1
2
3
9
Electrical installation
|
X 5M
1
8
7
10
9
S4S
e
f
STEP 2
Installer reference guide
139