9
|
Electrical installation
Installer reference guide
126
X6M
SWB2
*3V (3V: 1N~ 230 V)
*6V (6V: 1N~ 230 V)
*9W (3N~ 400 V)
Model (power supply)
*3V (3V: 1N~ 230 V)
X6M
SWB2
F1B
1
20A
I
I
2
Q1DI
1N~, 50 Hz
L
N
230 V AC
Connections to backup heater power supply
X6M
SWB2
F1B
1
3
20A
I
I
2
4
Q1DI
1N~, 50 Hz
L
N
230 V AC
ERGA04~08EAV3+V3A+V37 + EHSH/X(B)04+08P30+50EF
3
4
Daikin Altherma 3 R ECH₂O
4P678716-1 – 2022.01