Parameter list
System Setup screen
Setting
Value
Network
These are the network settings related to remote control of the VR-400UHD over LAN (WebRCS, Telnet).
Selects how to configure the IP address, subnet mask and default gateway.
Client
DHCP
Server
Static
Static Address
Manually configures the network connection when DHCP is set to "Static".
IP Address
192 168 10 10 (Example)
Subnet Mask
255 255 255 0 (Example)
Default Gateway
192 168 10 1 (Example)
State
Shows the current network settings.
IP Address
255 255 255 255 (Example)
Subnet Mask
255 255 255 255 (Example)
Default Gateway
255 255 255 255 (Example)
MAC Address
00 40 ab c6 44 00 (example)
Sets the password necessary to connect to the network (WebRCS, Telnet).
Password
When connecting a computer or other device on the same network to access the VR-400UHD, input the password that's set here.
Shows whether the password has been set.
Password State
Not set
Enabled
Current Password
New Password
Set Password
LCD / LED
LCD
Left
1–16
Brightness
Right
1–16
LED
Dimmer
1–16
Version
System
Details
Temp. / Fan
Temperature (Celsius)
Main FPGA
Sub FPGA
Fan (RPM)
At low speed, "Low" is indicated
Left
At high speed, the fan speed
Right
(RPM) is indicated
Test Pattern
Disabled, Color Bars, Hatch,
Pattern
Ramp
Scroll
Disabled, Enabled
Disabled, -18dB, -20dB
Test Tone
38
Ó
[SETUP] button
Ó
<System> tab
<Network>, <Password>, <LCD / LED>, <Version>, <Temp. / Fan>, <Test pattern>
Explanation
(bold text: default value)
Information required for connecting to the network such as the IP address from the DHCP server
on the LAN is automatically acquired.
Enables the DHCP server function. This automatically assigns the information required to
connect from the VR-400UHD to the network, such as a computer on the LAN.
Manually configures the IP address, subnet mask and default gateway.
Specifies the IP address as appropriate for the network to which the unit is connected.
Specifies the subnet mask as appropriate for the network to which the unit is connected.
Configures the default gateway according to the network to which this unit connects.
Displays the IP address.
Displays the subnet mask.
Shows the default gateway.
Displays the MAC address.
Password not set
Password set
When you want to change the password, enter the current password here.
When you're registering a password for the first time, you don't need to input this setting.
Enter the new password. The password can contain up to eight characters.
Registers/changes the password.
Adjusts the brightness of the left monitor on this unit.
Adjusts the brightness of the right monitor on this unit.
Adjusts the brightness when the buttons or indicators are lit.
Displays the version of the system program.
Displays the version for each processor.
Displays the processor temperature.
When the processor temperature exceeds 90ºC, a temperature alert appears. If the temperature
rises even more, the protective function begins to operate, which automatically shuts down the
power of the VR-400UHD.
You should keep the processor at a suitable temperature of around 70ºC.
Shows the speed (RPM) of the cooling fan on the left side of this unit (viewed from the front).
Shows the speed (RPM) of the cooling fan on the right side of this unit (viewed from the front).
Selects the test pattern to display.
Sets whether to scroll the test pattern.
Sets the volume of the test tone.