Due to product version upgrades or other reasons, the content of this document will be updated from time to time. Ruijie Networks reserves the right to modify the content of the document without any notice or prompt. This manual is for reference only. Ruijie Networks endeavors to ensure content accuracy and will not shoulder...
Intended Audience This document is intended for: Network engineers Technical support and servicing engineers Network administrators Technical Support Official Website of Ruijie Reyee: https://www.ruijienetworks.com/products/reyee Technical Support Website: https://www.ruijienetworks.com/support Case Portal: https://caseportal.ruijienetworks.com Community: https://community.ruijienetworks.com ...
Page 4
2. Note This manual provides the device installation steps, hardware troubleshooting, module technic al specifications, and specifications and usage guidelines for cables and connectors. It is intended for the users who have some experience in installing and maintaining network hardware. At the same time, it is assumed that the users are already familiar with the related terms and concepts.
Page 7
4.1.2 Checking after Program Startup (Recommended) ............29 5 Maintenance and Troubleshooting ....................30 5.1 General Troubleshooting Procedure ..................30 5.2 Troubleshooting Common Faults..................30 6 Appendix A Connectors and Connection Media ................31 7 Appendix B Lightning Protection ....................33 8 Appendix C Manufacturers and Models of Power Supplies ............35...
Hardware Installation and Reference Guide Product Overview Product Overview The 5/8-port plastic series switches include the following models: 10/100/1000 Base-T 10/100 Base-TX Auto- 1000Base-X Consol Model Auto-sensing sensing Ethernet Port SFP Port e Port Ethernet Port RG-ES05 RG-ES08 RG-ES05G RG-ES08G Note 1000Base-T is downward compatible with 100Base-TX and 10Base-T.
Hardware Installation and Reference Guide Product Overview Power Consumption Less than 2.5W Operating 0℃ to 40℃ (32° F to 104° F) Temperature -40℃ to 70℃ (-40° F to 158° F) Storage Temperature Operating Humidity 10% to 90% RH Storage Humidity 5% to 95% RH Not supported Temperature Warning...
Hardware Installation and Reference Guide Product Overview Figure 1-1 Figure 1-1 Appearance of RG-ES05 Front Panel Figure 1-2 Figure 1-2 Front Panel of RG-ES05 Note: 1. 10/100Base-TX Ethernet port 2. RJ45 port status LED 3. System status LED 4. DC power port 1.1.3 Heat Dissipation The RG-ES05 adopts natural heat dissipation, thereby ensuring normal function of the device.
Hardware Installation and Reference Guide Product Overview Panel State Meaning Identification The port is not connected. RJ45 port Solid on The port is connected at 10/100 Mbps. status The port is receiving or sending traffic at Blinking 10/100 Mbps. RG-ES08 1.2.1 Device Specification Table 1-2...
Hardware Installation and Reference Guide Product Overview Not supported Temperature Not supported Warning Accessing Optical Module Not supported Information GB9254-2008 EN 55032: 2015+A11:2020 EN 55035: 2017+A11: 2020 EMC Standards EN 61000-3-2: 2019 EN 61000-3-3: 2013+A1:2019 EN 300 386 V2.1.1(2016-07) GB4943-2011 Security Standards EN 62638-1...
Hardware Installation and Reference Guide Product Overview Figure 1-3 Figure 1-3 Appearance of RG-ES08 Front Panel Figure 1-4 Figure 1-4 Front Panel of RG-ES08 Note: 1. 10/100Base-TX Ethernet port 2. RJ45 port status LED 3. System status LED 4. DC power port 1.2.3 Heat Dissipation The RG-ES08 adopts natural heat dissipation, thereby ensuring normal function of the device.
Hardware Installation and Reference Guide Product Overview Panel State Meaning Identification The port is not connected. RJ45 port Solid on The port is connected at 10/100 Mbps. status LED The port is receiving or sending traffic at Blinking 10/100 Mbps. RG-ES05G 1.3.1 Device Specification...
Hardware Installation and Reference Guide Product Overview Not supported Temperature Not supported Warning Accessing Optical Module Not supported Information GB9254-2008 EN 55032: 2015+A11:2020 EN 55035: 2017+A11: 2020 EMC Standards EN 61000-3-2: 2019 EN 61000-3-3: 2013+A1:2019 EN 300 386 V2.1.1(2016-07) GB4943-2011 Security Standards EN 62638-1...
Hardware Installation and Reference Guide Product Overview Figure 1-5 Figure 1-5 Appearance of RG-ES05G Front Panel Figure 1-6 Figure 1-6 Front Panel of RG-ES05G Note: 1. 10/100/1000Base-T Ethernet port 2. RJ45 port status LED 3. System status LED 4. DC power port 1.3.3 Heat Dissipation The RG-ES05G adopts natural heat dissipation, thereby ensuring normal function of the device.
Hardware Installation and Reference Guide Product Overview Panel State Meaning Identification System status Solid on The switch is operational. The port is not connected. RJ45 port Solid on The port is connected at 10/100 Mbps. status LED The port is receiving or sending traffic at Blinking 10/100 Mbps.
Hardware Installation and Reference Guide Product Overview Operating 10% to 90% RH Humidity Storage Humidity 5% to 95% RH Not supported Temperature Not supported Warning Accessing Optical Module Not supported Information GB9254-2008 EN 55032: 2015+A11:2020 EN 55035: 2017+A11: 2020 EMC Standards EN 61000-3-2: 2019 EN 61000-3-3: 2013+A1:2019 EN 300 386 V2.1.1(2016-07)
Hardware Installation and Reference Guide Product Overview Figure 1-7 Figure 1-8 Appearance of RG-ES08G Front Panel Figure 1-8 Figure 1-9 Front Panel of RG-ES08G Note: 1. 10/100/1000Base-T Ethernet port 2. RJ45 port status LED 3. System status LED 4. DC power port 1.4.3 Heat Dissipation The RG-ES08G adopts natural heat dissipation, thereby ensuring normal function of the device.
Page 20
Hardware Installation and Reference Guide Product Overview Panel State Meaning Identification The port is not connected. RJ45 port Solid on The port is connected at 10/100/1000 Mbps. status LED The port is receiving or sending traffic at Blinking 10/100/1000 Mbps.
Hardware Installation and Reference Guide Preparation before Installation Preparation before Installation Safety Suggestions Caution To avoid personal injury and equipment damage, please carefully read the safety suggestions before you install the 5/8-port plastic series switch. The following safety suggestions do not cover all possible dangers. 2.1.1 Installation ...
Hardware Installation and Reference Guide Preparation before Installation Direct or indirect touch through a wet object on high-voltage and mains supply may bring a fatal danger. If a power supply system is equipped with a leakage protector (also referred to as "leakage current switch" or "leakage current breaker"), the rated leakage action current of each leakage protector is greater than twice of the theoretical maximum leakage current of all the power supplies in the system.
Hardware Installation and Reference Guide Preparation before Installation 2.2.2 Temperature and Humidity To ensure the normal operation and prolong the service life of 5/8 -port plastic series switch, you should keep proper temperature and humidity in the equipment room. If the equipment room has temperature and humidity that do not meet the requirements for a long time, the equipment may be damaged.
Hardware Installation and Reference Guide Preparation before Installation Apart from dust, the salt, acid and sulfide in the air in the equipment room must also meet strict requirements, as such poisonous substances may accelerate the corrosion of the metal and the aging of some parts. The equipment room should be protected from the intrusion of harmful gases such as sulfur dioxide, sulfured hydrogen, nitrogen dioxide, and chlorine), whose require ments are listed in Table 2-3.
Page 25
Hardware Installation and Reference Guide Preparation before Installation Meters Multimeter Note The tool kit is customer-supplied.
Hardware Installation and Reference Guide Product Installation Product Installation Note Please ensure that you have carefully read Chapter 2. Confirmations before Installation Before installation, please confirm the following points: Whether ventilation requirements are met for the switch Whether the requirements of temperature and humidity are met for the switch ...
Hardware Installation and Reference Guide Product Installation (3) Put screws (ST4.2x20 recommended) into the wall anchors and ensure that the distance between the inner side of the screw head and the outer edge of the wall anchors not be smaller than 2.5 mm (0.10 in.) so that the device can be securely mounted on the screws.
Hardware Installation and Reference Guide Product Installation Caution The device must be installed and operated in the place that can restrict its movement. Checking after Installation Caution Before checking the installation, switch off the power supply so as to avoid any personal injury or damage to the component due to connection errors.
Page 29
Hardware Installation and Reference Guide Product Installation (2) Tap the Topology button, and select the existing managed device. To add an unmanaged downlink switch by scanning its QR-code, select Scan to Add.
Page 30
Hardware Installation and Reference Guide Product Installation (3) After the device is detected, select its uplink port. And the device is added successfully.
Page 31
Hardware Installation and Reference Guide Product Installation...
Hardware Installation and Reference Guide Product Installation 3.4.2 Adding Unmanaged Device Manually (1) Tap Topology to enter the topology page. (2) Tap the Topology button, and select the existing managed device. To add an unmanaged downlink switch manually, select Manually Add.
Page 33
Hardware Installation and Reference Guide Product Installation...
Page 34
Hardware Installation and Reference Guide Product Installation (3) Select the device model and its uplink port, and the device is added successfully.
Page 35
Hardware Installation and Reference Guide Product Installation...
Hardware Installation and Reference Guide System Debugging System Debugging Startup Check 4.1.1 Checking before the Device is Powered on The power cable is correctly connected. The power supply voltage complies with the requirement of the switch. 4.1.2 Checking after Program Startup (Recommended) After power-on, you are recommended to perform the following checks to ensure the normal operation of follow- up configurations.
Hardware Installation and Reference Guide Maintenance and Troubleshooting Maintenance and Troubleshooting General Troubleshooting Procedure Troubleshooting Common Faults Symptom Possible Causes Solution The status indicator Check whether the power socket at the The power module does not work. is not on after the equipment room is normal and whether the The power cable is in loose contact.
Appendix A Connectors and Connection Media 1000BASE-T/100BASE-TX/10BASE-T Ports The 1000BASE-T/100BASE-TX/10BASE-T is a port that supports adaptation of three rates, and automatic MDI/MDIX Crossover at these three rates. The 1000BASE-T complies with IEEE 802.3ab, and uses the cable of 100-ohm Category-5 or Supper Category- 5 UTP or STP, which can be up to 100 m.
Page 39
Figure A-3 Connections of the Twisted Pairs of the 100BASE-TX/10BASE-T Optical Fiber Connection For the optical fiber ports, select single-mode or multiple-mode optical fibers for connection according to the fiber module connected. The connection schematic diagram is shown in Figure A-4: Figure A-4 Optical Fiber Connections...
Appendix B Lightning Protection Installing AC Power Arrester (lightning protection cable row) The external lightning protection cable row shall be used on the AC power port to prevent the switch from being struck by lightning when the AC power cable is introduced from the outdoor and directly connected to the power port of the switch.
Page 41
Tools: Cross or straight screwdriver, Multimeter, Diagonal pliers Installation Steps: Tear one side of the protection paper for the double-sided adhesive tape and paste the tape to the framework of the Ethernet port arrester. Tear the other side of the protection paper for the double -sided adhesive tape and paste the Ethernet port arrester to the switch framework.
Reversed direction of the arrester installation. You shall connect the external network cable to the “IN” end and connect the switch Ethernet port to the “OUT” end. Poor arrester grounding. The length of the grounding line should be as short as possible to ensure that it is in good contact with the switch grounding terminal.