ClimateMaster AVB32V02R Owner's Manual & Installation Instructions page 40

Programmable digital thermostat residential
Table of Contents

Advertisement

About Advanced Features & Operation
Deadband
db 3
(non-adj. 2˚)
3rd Stage
2nd Stage
strip heat
turn on
turn on
The above figure assumes the minimum on time for the prior stage has been met
to allow the next stage to turn on, once the deadbands have been exceeded.
Emergency Heat
Only available if you have a Heat Pump installed. To initiate the
Emergency Heat feature, press the FAN button. While holding the FAN
button press the UP button, for two seconds. The display will read 'EM
HEAT' (Emergency Heat).
FAN
Emergency Heat
During Emergency Heat operation the thermostat will turn on the fan
and the Aux strip heat when there is a demand for heat. Also during
Emergency Heat, heatpump operation will be unavailable.
Exit Emergency Heat
Follow the same steps as entering Emergency Heat by pressing the FAN
and UP buttons, for two seconds. During Emergency Heat, only OFF and
HEAT modes are available by pressing the MODE button.
Heating
Deadband
Deadband
db 2
db 1
(adj. 0-10˚)
(adj. 1-6˚ )
1st Stage
turn on
Setpoint
TEMPERATURE
DECREASE
Press for
Deadband
db 1
(adj. 1-6˚ )
Heat
Cool
Setpoint
35
Cooling
Deadband
db 2
(adj. 0-10˚ )
1st Stage
2nd Stage
turn on
turn on
INCREASE