ClimateMaster AVB32V02R Owner's Manual & Installation Instructions page 21

Programmable digital thermostat residential
Table of Contents

Advertisement

Basic Operation
Selecting Your Desired Humidity
This thermostat is a perfect solution for reducing space humidity when
using Climate Master two stage system with ClimaDry. To control dehu-
midification, be sure to set AUX USE (Setup Step 29) to 'dehumidifier'.
Conversely, you can control a humidifier by setting AUX USE (Setup
Step 29) to humidifier'. You cannot control both.
To adjust the humidify/dehumidify setpoint, first press/hold MODE for two
seconds. The screen will change to show:
Current Humidity
Next, press MODE
again. The screen
will show:
Adjust the desired set
temperature with these buttons
Finally, press MODE to return to normal operation.
16
Daily Maximum
Humidity
Daily Minimum
Humidity
Current
Humidity
Humidify Setpoint
(0 - 99%)
Current
Humidity
Dehumidify Setpoint
(0 - 99%)