ClimateMaster AVB32V02R Owner's Manual & Installation Instructions page 34

Programmable digital thermostat residential
Table of Contents

Advertisement

User Setup
Dehum with Cool Only or Hum with
Heat Only (Setup Step 34)
Depending on how AUX USE (Setup Step
29) is configured, this step is used to
control whether the equipment must be
running before the D / H output can turn on.
Humidifying for example, you might not want
to turn on the humidifier unless the thermostat
is calling for heat. Answering ON to this step
will mean no dehumidifying unless cool is
active or no humidifying unless heat is active.
Answering OFF to this step will allow the D /
H output to simply reflect whether the room
humidity is above the dehumidify setpoint
(AUX USE = Dehum) or below the humidify
setpoint (AUX USE = HUM).