Section A: Before You Start; Pre-Installation Checklist - Montigo Divine H36PV Installation & Maintenance Manual

Table of Contents

Advertisement

H36PVN Power Vent Indoor Gas Fireplace

Section A: Before You Start

Important Message
Save these Instructions
The H36PV Power Vent fireplaces must be installed in
accordance with these Instructions. Carefully read all the
Instructions in this manual first. Consult the Local Gas Branch to
determine the need for a permit prior to starting the installation.
It is the responsibility of the installer to ensure this fireplace is
installed in compliance with the manufacturers instructions and
all applicable codes.
BEFORE YOU START:
NOTICE
Installation and repairs should be done by an authorized gas fireplace service technician.
The appliance should be inspected before use and at least annually by a professional. More
frequent cleaning may be required due to excessive lint from carpeting, bedding material,
etc. It is imperative that control compartments, burners and circulating air passageways of
the fireplace are kept clean.
CAUTION
Due to high operating temperatures, this appliance should be located out of traffic &
away from furniture and draperies.
Children and adults should be alerted to the hazards of the high surface temperature,
which could cause burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the
appliance.
Clothing or other flammable materials should not be placed on or near the appliance.
DANGER
When this appliance is installed directly on any combustible material other than wood
flooring, it must be installed on a metal or wood panel extending the full width and
depth of the appliance or a fire will occur causing serious injury, property damage or
even death.
WARNING
Any safety screen, guard, or barrier removed for servicing an appliance must be replaced
prior to operating the appliance.
Page 4
Installation
Installation

Pre-Installation Checklist

■ Determine the desired install location of your fireplace.
■ See Section 1, Dimensions on Page 5, and refer to the
Framing Section 2 for details.
■ Select your type and location of your Power Vent
run: Roof Mounted (EDVRSPV58) or Wall Mounted
(EDVWSPV58) or LDVPV58 (Inline Power Vent).
■ Your termination location should be selected to provide
the shortest possible vent run.
■ Lay out the Vent run; calculating the required elbows
and straight runs of 5"/8" flex and/or rigid pipe.
■ Refer to the Section 4 on Page 10, "Installing the Power
Vent" for details.
■ Montigo supplies 20' of low voltage wire, which can be
spliced to any length. This wire CANNOT run in conduit
with any other wire.
■ Refer to Section 5 on Page 18, for Wiring Details.
■ The gas connection is located on the bottom side of the
fireplace.
■ Refer to local codes and guidelines for installation
requirements.
■ Installation and repairs should be done by a qualified
contractor and must conform to:
• Installations in Canada must conform to the
current CAN/CGA B-149.1 and .2 Gas Installation Code and
local regulations.
• Installations in the USA must conform to local
codes, or in the absence of local codes to the National
Fuel Gas Code, ANSI Z223.1.
• See Appendix C for installation within the State
of Massachusetts. This fireplace must comply with
NFPA-54 Chapter 10.
■ Refer to Section 6 Page 24, "Installing the Gas Line" for
Details.
Understanding the Basic Operation
Residential H36PV fireplace
To operate the fireplace, Montigo has supplied and installed
twenty feet of low voltage wire to this electrical control panel.
Connect the two wire harness to a standard single pole ON/
Off switch located at a location of your choice. You may also
extent these wires to any length, as long as you select a wire
of equal quality.
XG0649 - 080921