Venting Components
The following venting components and associated Montigo part
numbers are available for the PVHEX47-200
Termination & Fan
Motor 4"/7" (Includes
mounting frame)
Flex Sections
Rigid Sections
Elbows
Power Cord Harnesses
Connection and installation of the vent components
should adhere to the following guidelines:
Use any combination of rigid and flex pipe as required and in any
orientation (Male connectors can face in any direction).
Flex sections may be stretched up to 50% of their total length (e.g.
a 24" section maybe stretched to 36").
Ensure the pipe ends male to female slide in a minimum of 1 1/2"
of overlap.
Connect all vent sections using a minimum of three sheet metal
screws on the outer and inner pipe flue.
Ensure all runs are supported with a minimum of 3 supports per 10'
of venting.
When hanging/ supporting venting, ensure that 1" clearance is
maintained on sides and bottom of vent runs and 2" above horizontal
vent runs to any combustible material.
Rigid pipe may be cut less than half way from the female end only.
Ensure when cutting sections of rigid pipe to maintain integrity of
internal supports.
Place the springs, supplied with the pipe kit, between the outer and
inner pipes to keep the pipes separate and avoid any possible hot spots.
Montigo recommends the use of a flex section for the final pipe
connected directly to the fireplace offering greater flexibility of
installation and absorption of movement.
Firestops must be installed as required by National & local codes.
14 1/16"
14 1/16"
14 1/4"
14 1/4"
12 1/8"
12 1/8"
XG0649 - 080921
Installation
Installation
:
PVHEX47-200
MLF-1 (12" Section)
11 1/16"
MLF-2 (24" Section)
MFL-3 (36" Section)
MFL 4 (48" Section)
MEXT-1 (12" m/f Section)
MXT-20 (20" Section)
MEXT-2 (24" m/f Section)
11 1/16"
MEXT-3 (36" m/f Section)
MEXT-4 (48" m/f Section)
MEL-90MM (m/m 90º Elbow
MEL-90FF (f/f 90º Elbow
MEL-90FM (f/m 90º Elbow)
MEL-45FM (f/m 90º Elbow)
EPVH-10 foot power cord & harness
9 3/4"
REF.
EPVH-20 foot power cord & harness
EPVH-40 foot power cord & harness
EPVH-60 foot power cord & harness
EPVH-80 foot power cord & harness
EPVH-100 foot power cord & harness
12 5/16"
12 5/16"
1 1/2"
1 1/2"
When passing vent pipe through a wall use a heat shield.
Montigo recommends that all exterior corners and joints be
sealed with exterior caulking. However, we encourage you
to consult your Building Envelope Engineer or Waterproofing
Consultant for further recommendations.
Refer to Appendix A - Power Vent locations, to ensure the planned
Vertical Power vent location is acceptable.
9 3/4"
11 1/16"
14 1/16"
14 1/4"
14 1/4"
12 1/8"
4 9/16"
4 9/16"
9 11/16"
9 11/16"
7
4
4
9 11/16"
H36PVN Power Vent Indoor Gas Fireplace
10 9/16"
9.0
11 1/16"
9 3/4"
REF.
14 1/16"
12 5/16"
12 1/8"
1 1/2"
1 1/2"
7
9 11/16"
4
9 3/4"
12 5/16"
9 11/16"
4
4
Page 15