Montigo H38DF-PFC Installation, Operation & Maintenance Manual

Gas fireplace

Advertisement

H38DF-PFC
Warning:
Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to this manual. For assistance or additional
information consult a qualified installer, service agency or the gas supplier.

Safety Notice:

Glass doors on gas fireplaces are extremely hot while the fireplace is on and remain
hot even after the fireplace has been turned off. Safety screens are available and
can reduce the risks of severe burns. Please keep children away from the fireplace
at all times.

For Your Safety:

Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
XG0816
Canadian Heating Products Inc. Langley, BC V4W 4A
Installation Operation & Maintenance Manual
Check local codes and read all instructions prior to installation.
Series Gas Fireplace
®
C
US
www.montigo.com
H38DF-PFC
HL38DF-PFC
HLS38DF-PFC
Warning:
mation in these instructions is not
followed exactly, a fire or explosion
may result causing property dam-
age, personal injury or death.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical
switch; do not use any phone in
your building.
Immediately call your gas
supplier from a neighbor's
phone. Follow the gas supplier's
instructions.
If you cannot reach your gas
supplier, call the fire department.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
Montigo Del Ray Corp. Ferndale, WA 98248
If the infor-
Installer: Leave this manual
with the appliance.
Consumer: Retain this
manual for future reference.
100210

Advertisement

Table of Contents
loading

Summary of Contents for Montigo H38DF-PFC

  • Page 1: Safety Notice

    • Installer: Leave this manual with the appliance. • Consumer: Retain this ® manual for future reference. XG0816 Canadian Heating Products Inc. Langley, BC V4W 4A Montigo Del Ray Corp. Ferndale, WA 98248 100210...
  • Page 2: Table Of Contents

    H*38DF-PFC* Indoor Gas Fireplace Warning: Read this manual before installing, operating or troubleshooting this appliance. Please retain this owner's manual for future reference. Table of Contents ▪ ......14 Section 3-3-2: Venting Components Safety Alert Key ▪ ......... 15 Section 3-3-3: Heat Shields Introduction ................
  • Page 3: Safety Alert Key

    INTRODUCTION Congratulations on your purchase of a Montigo Fireplace. With over 30 years of experience, Montigo is committed to providing This installation, operation and maintenance manual is applicable you with a gas fireplace that is not only a beautiful addition to your to the models described below.
  • Page 4: Installation

    Should it be impossible to meet the venting requirements laid „ out in Section 3: Venting, please contact Montigo regarding the BEFORE YOU START: use of a Montigo Power Vent. Lay out the Vent run; calculating the required elbows and straight „...
  • Page 5: Installation Overview And Product Dimensions

    H*38DF-PFC* Indoor Gas Fireplace Installation Section 1: Installation Overview and Product Dimensions Please review the Installation Checklist on Page 4 for general information on preparing for a successful installation of your fireplace. The H*38PF* fireplace may be installed in any location that maintains proper clearances to air conditioning ducts, electrical wiring and plumbing. Safety, as well as efficiency of operation, should be considered when selecting the fireplace location.
  • Page 6: Framing The Fireplace

    H*38DF-PFC* Indoor Gas Fireplace Installation Section 2: Framing Frame in the enclosure for the unit with framing materials. The Top Vent Cieling level framed opening for the assembled fireplace is 23 3/4" wide, x 44" high x 41" deep, see Figure 2 Non-Combustible materials.
  • Page 7: Clearances

    H*38DF-PFC* Indoor Gas Fireplace Installation Installing The Standoffs Clearances To avoid elevated mantel temperatures, all H*38PF*-Series gas When installing a shelf over the top of the fireplaces, the following fireplaces are required to have the supplied standoffs installed. guidelines must be adhered to: The fireplace is supplied with two standoffs.
  • Page 8: The Direct Vent System

    Installation Section 3: Venting Montigo supplies a variety of direct venting and termination options. 4. Install the (5" and 8") collars to the rear vent outlet using the The direct vent termination location MUST be selected such that included hardware, as illustrated Figure 9a.
  • Page 9: Section 3-2: Installing A Roof Mounted Termination

    H*38DF-PFC* Indoor Gas Fireplace Installation Section 3-2: INSTALLING A ROOF MOUNTED DIRECT VENT PVTK1 TERMINATION (PVTK-1) Termination This section applies to installations where the direct vent termi- 2’ min. nation will be roof mounted. Section 3-2-1: VENTING LAYOUT Support ring Selection of components and details of venting lay out should Support plate 32’...
  • Page 10: Section 3-2-2: Venting Components

    Figure 11c. Rear vent, Roof mounted venting (1 = 90° bend). Montigo recommends the use of a flex section for the final pipe „ connected directly to the fireplace offering greater flexibility of...
  • Page 11: Section 3-3: Installing A Wall Mounted Termination

    H*38DF-PFC* Indoor Gas Fireplace Installation Section 3-3: INSTALLING A WALL MOUNTED DIRECT VENT 4). Installation of termination from inside structure TERMINATION A Termination with a MOSR Frame is installed from the inside of the This section applies to installations where the direct vent termi- structure.
  • Page 12: Section 3-3-1: Venting Layout

    All through-the-wall terminations beyond 3' of the fireplace must 46” „ within shaded area. have a Montigo Heat Shield (RHS8) installed. See Section 3-3-3. If your installation does not fall 42 ” within the venting graph para- Once the proposed venting layout has been determined refer to „...
  • Page 13 53” Flex 42” If your installation does not fall within the venting graph para- 33” meters, please contact Montigo 12” for Power Venting options. Figure 17. Rear Vent Venting Graph for wall mounted terminations. Part No. XG0816 - 100210 Page 13...
  • Page 14: Section 3-3-2: Venting Components

    „ and inner pipes to keep the pipes separate and avoid any possible hot spots. Montigo recommends the use of a flex section for the final pipe „ connected directly to the fireplace offering greater flexibility of installation and absorption of movement.
  • Page 15: Section 3-3-3: Heat Shields

    H*38DF-PFC* Indoor Gas Fireplace Installation Section 3-3-3: Heat Shields Installing a Wall Mounted RHS101 Heat shield. Installing a Wall Mounted RHS8 Heat shield The RHS101 Heat shield MUST be used where the RHS8 Termination (Figure 19 and 19a) CANNOT be used. Use the RHS101 within 36" The RHS8 Heat shield CANNOT be used WITHIN 36"...
  • Page 16: Wiring

    H*38DF-PFC* Indoor Gas Fireplace Installation Installation Section 4: Wiring Honeywell (Q3450) Pilot Assembly Pilot Electrical Harness Connector Honeywell Gas Control (SV9501M) Gas Control Connector Junction Box Fan Plug Receptacle Black 115VAC White 24VAC Green Gnd Screw 40 VA Transformer Wall Switch Figure 20.
  • Page 17: Installing The Gas Line

    „ a 1/8” N.PT. plug to be fitted with a hose barb. WARNING! Montigo requires a service shut off valve be located in an „ accessible location to isolate the gas supply. When pressure testing the fireplace, Gas line, and input system follow the appropriate local codes or your area.
  • Page 18: Finishing

    H*38DF-PFC* Indoor Gas Fireplace Installation Installation Section 6: Finishing Painting: Finishing Around the Fireplace Special care is recommended by the Master Painters and Decorators Combustible mantels and mouldings may be safely installed over the Association, when painting the fireplace surrounds, to select and apply top and on the front of the fireplace provided that they do not project a quality Alkyd sealer prior to the applying of latex paints.
  • Page 19: Installing And Removing The Door

    H*38DF-PFC* Indoor Gas Fireplace Installation Installation Section 7: Installing & Removing the Door Removing the door: The H*38PF* doors are removed in a few simple steps. Follow these Step 5: below to remove the Horizontal access panel, unlatch the door buckles Ensure the tool is firmly and, remove the door.
  • Page 20: Installing The Accessories

    H*38DF-PFC* Indoor Gas Fireplace Installation Section 8: Installing the Accessories Installing the Logset The H38PF* is supplied with eight (8) fibre logs. The two small bottom logs ("A" ) are mounted on the burner grate by placing them diago- Log C nally onto the supplied Log stands.
  • Page 21: Installing The Hl38Pf* Firestones

    H*38DF-PFC* Indoor Gas Fireplace Installation Installing Firestones in N.G. (Natural Gas) Fireplaces Installing Firestones in L.P. (Propane) Fireplaces The HL38PFN/LI2 is supplied with firestones. Remove the Door and Propane HL38PFN/L Fireplace is supplied with firestones. Remove trim as shown in the previous Instruction. Follow these instructions to the Door and trim as shown in the previous Instruction.
  • Page 22: Operation

    H*38DF-PFC* Indoor Gas Fireplace Operation Installation Section 9: Start-up Sequence Models Included H38PFN H38PFL with Continuous Pilot HL38PFN HL38PFL with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING! If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 23 H*38DF-PFC* Indoor Gas Fireplace Operation Installation with Honeywell Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING! If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. If you cannot reach your gas supplier, call the Fire A.
  • Page 24 H*38DF-PFC* Indoor Gas Fireplace Operation Installation Models Included H38PFNI H38PFLI Proflame SIT Electronic Ignition HL38PFNI2 HL38PFLI2 with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING! If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 25: Maintenance

    H*38DF-PFC* Indoor Gas Fireplace Maintenance Lighting Instructions Hi-Lo Burner Adjustment: (SIT Nova 820). See pages 22 to 23. The H*38PF* is equipped with an adjustable burner, allowing you to General raise or lower the flames. To adjust the flames, locate the black knob Have the fireplace and installation inspected yearly.
  • Page 26: Troubleshooting

    H*38DF-PFC* Indoor Gas Fireplace Maintenance Models Included Troubleshooting: Troubleshooting Models Included H38PFN HL38PFN (SIT - IPI Electronic) (SIT Nova 820). H38PFNI HL38PFNI2 H38PFL HL38PFL H38PFLI HL38PFLI2 The following is a troubleshooting chart of possible problems: 1. Locate the lead to the battery backup, (remove) PROBLEM CORRECTIVE ACTION (Refer to schematic, below)
  • Page 27: Spare Parts List

    H*38DF-PFC* Indoor Gas Fireplace Maintenance Spare Parts List H38PF* HL38PF* NG Gas Valve RGC1006 RGC1006 LP Gas Valve RGC1005 RGC1005 NG Pilot RPA020 RPA020 LP Pilot RPA021 RPA021 NG Burner RBH3801 LP Burner RBH3802 NG Oriface R0R1120 LP Oriface R0R1121 Door RDTH38 RDTH38...
  • Page 28: Termination Locations

    H*38DF-PFC* Indoor Gas Fireplace Appendix A - Termination Locations A = clearance to the termination frame above grade, veranda, porch, deck, clearance above paved sidewalk or a paved driveway located on public † or balcony [16 inches (41 cm) minimum] property [*7 feet (2.1 m) minimum] B = clearance to door, or sides and top of window, that may be opened [16 P = c l e a r a n c e u n d e r v e r a n d a , p o r c h , d e c k , o r b a l c o n y...
  • Page 29: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 30: State Of Massachusetts

    H*38DF-PFC* Indoor Gas Fireplace Appendix C - State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by adding the following additional requirements:...
  • Page 31 H*38DF-PFC* Indoor Gas Fireplace Notes Part No. XG0816 - 100210 Page 31...
  • Page 32 H*38DF-PFC* Indoor Gas Fireplace Notes Part No. XG0816 - 100210 Page 32...
  • Page 33 H*38DF-PFC* Indoor Gas Fireplace Notes Part No. XG0816 - 100210 Page 33...
  • Page 34 XG0207 - 081310 Montigo Del Ray Corp. Canadian Heating Products Inc. Ferndale, WA 98248 Langley, BC V4W 4A1...