EN
Basic mode (heater on)
The top row shows the sauna room temperature. The bottom row shows the remaining on-time.
Both indicator lights glow.
Basic mode (pre-setting time running, heater off)
The decrease of remaining pre-setting time is shown until zero appears, after which the heater is
switched on.
Figure 3a. Settings menu structure, basic settings
6
BASIC SETTINGS/GRUNDEINSTELLUNGEN
Press the MENU button to open the settings menu.
Sauna room temperature
The display shows the sauna room temperature setting. Temperature indicator light blinks.
Change the setting to the desired temperature with the – and + buttons. The range is
40–110 ºC.
Press the MENU button to access the next setting.
Remaining on-time
Press the + and – buttons to adjust the remaining on-time.
Example: the heater will be on for 3 hours and 40
minutes.
Pre-setting time (timed switch-on)
Press the + button until you overstep the maximum on-time. Temperature indicator light
switches off. Pre-setting time symbol blinks on the screen.
Select the desired pre-setting time using the – and + buttons. The time changes in 10
minute steps.
Example: the heater will start after 10 minutes.
Press the MENU button to exit.