• Setup, commission, and operate system according to this instruction, and as supplemented in
the HVAC equipment Installation Instructions, to assure a smooth and trouble free start-up.
• Note that some detailed equipment configuration and service information may be included
with the equipment instructions. Please refer to the equipment installation instruction
manuals, and applicable technical training materials, for all devices for complete
information.
4.2. Check Equipment
Inspect equipment. File a claim with shipping company prior to installation if shipment is
damaged or incomplete.
4.3. Location
ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury or death.
Disconnect power before routing control wiring.
All wiring must comply with national, state, and local codes.
4.3.1. Wall Control
The Ion System Control is the command center for the Ion System. It should be located where it
is easily accessible and visible to the adult homeowner or end user. For accurate temperature
measurement, the following guidelines should be followed:
The Ion Control, Remote Room Sensors and Smart Sensors (when available) SHOULD be
mounted:
• Approximately 5-ft (1.5 m) from the floor.
• Close to or in a frequently used room, preferably on an inside partitioning wall.
• On a section of wall without pipes or ductwork.
The Ion System Control and Sensors SHOULD NOT be mounted:
• Close to a window, on an outside wall, or next to a door leading to the outside.
• Exposed to direct light or heat from a lamp, sun, fireplace, or other temperature-radiating
objects which could cause a false reading.
• Close to or in direct airflow from supply registers.
• In areas with poor air circulation, such as behind a door or in an alcove.