Information Section. To return to the previous screen, touch BACK. To exit, touch DONE. See
Dealer Contact Information Section.
6.5.11. Energy Tracking
NOTE: Energy Tracking is only available for applicable equipment. See The Product Data for
the equipment in question to see if Energy Tracking is available for that device. Both indoor and
outdoor units must have energy tracking capability for this feature to function fully. See System
Product Data for compatible units and more information.
NOTE:
This menu item allows the installer to view the energy usage of each piece of equipment
connected to the system. To return to the previous screen, touch BACK. To exit the Service
menus, touch DONE.
A14231
6.6. Refrigerant Charging: SmartSense Systems
This feature is only available on specific units. See the Ion System Control Product Data for
compatible units and more information. For multi-stage heat pumps and AC units, a refrigerant
charging menu is available to aid in the proper charging of the system. Enter the menu from the
service screens by touching REFRIGERANT CHARGING.The option for HTG CHECK
CHARGE is only available for heat pump units, and not available in AC units.
NOTE: See the outdoor equipment Installation Instructions for information on what conditions
CHARGING COOLING and HTG CHECK CHARGE are available.
6.6.1. Charging
See the Ion System Control Product Data for compatible units and more information. Within the
CHARGING COOLING or HTG CHECK screens, the installer will have the ability to enter
the LINESET length and the VAPOR LINE diameter. After the selections are made, touch
NEXT.
• Lineset: Selectable from 5 to 200 feet
NOTE: For multi-stage product, 100 feet is the maximum allowed refrigerant line length.
• Vapor line: Selectable with various diameters by using the up and down buttons
42