4.6.1. Bypass Humidifier
A bypass humidifier should be wired directly to the furnace or fan coil HUM and 24VAC COM
terminals. The Ion System Control will automatically energize the HUM output during a call for
humidification.
4.6.2. Fan Powered Humidifiers
Most fan powered humidifiers produce internal 24VAC in order to energize upon a switch or
contact closure. For this application, a 24VAC N.O. Isolation Relay (DPST) MUST be used to
prevent mixing the internal humidifier power with the indoor equipment transformer. Applying
24VAC isolation relay coil to furnace or fan coil HUM and COM terminals will allow the Ion
System Control to automatically energize the HUM output during a call for humidification. The
N.O. relay contacts will be used to energize the humidifier. See Fan Powered Humidifier
installation instructions for more details.
5. Commissioning
This section addresses initial power up (or commissioning) of a new Ion System Control. The
control will communicate and identify all components in the Ion System. The following is a
typical example for an ICP communicating variable-speed furnace / fan coil with a 2-stage
air-conditioner / heat pump (including dual fuel system). The process may vary for other types
of systems. See the ICP communicating HVAC equipment Installation Instructions for more
details, as provided.
5.1. Searching for Indoor Unit
The Ion System Control will light up and display the Ion System logo and then begin the
commissioning process by displaying "Searching for indoor unit".
NOTE: If the Ion System-compatible indoor equipment (package unit indoor section, gas
furnace or fan coil) cannot be found, the control will display "Indoor unit not found". This
MUST be corrected before the initial power up sequence can continue, proceeding to the next
section, "Searching for outdoor unit." If it is not corrected, the Ion System Control will go into
its DEMO operating mode. If a control is operating in Demo mode and you wish to install it
with equipment, navigate to the Installer menu and perform a re-install to re-learn the
equipment.
TIP: Troubleshoot communication bus problems by removing all but the indoor unit and
system control from the communication bus circuit. As each bus segment is verified, connect
the next component and continue to troubleshoot as required.