For SmartSense heat pumps, you can select the stage at which the heat pump will exercise.
During the checkout, the stage and time can be changed by pressing the Change button on the
checkout status screen.
After the selections are made, touch START.
NOTE: Airflows during Checkout modes are fixed to the EFFICIENCY setting and are
independent of other airflow settings. To view airflows for normal air conditioning cooling
mode, exit the CHECKOUT screen and apply a heating demand to the system.
• Low Cool Run Time: Selectable from 0 to 120 minutes. Default = 5 minutes
• High Cool Run Time: Selectable from 0 to 120 minutes. Default = 5 minutes
6.4.7. Humidifier
The humidifier can be exercised On and Off with this menu option. To end the humidifier
checkout, touch STOP.
• Humidifier Check: On or Off
6.4.8. Zoning (If Applicable)
NOTE: This feature is only available with specific ICP communicating indoor units. See the
Iont System Control Product Data for compatible units and more information.
6.4.8.1. Airflow Limits
Because there is no bypass damper, the zone airflow limit check will allow the installer to assess
the airflow noise generated by the system providing the maximum amount of airflow to each
zone. Touch AIRFLOW LIMITS: When START is touched, the selected zone's damper will
fully open, all others will close, and the indoor unit will provide the maximum airflow for that
zone (as selected in SETUP — ZONING, Airflow Limits). If the airflow noise is objectionable,
the installer can select a lower airflow noise limit. If the noise is not objectionable, the installer
should leave HIGH selected, or even NO LIMIT.
NOTE: Selecting a lower airflow noise limit may decrease the homeowner's comfort in that
zone.
Touch the Left (<) or Right (>) buttons to change the desired zones. Once the proper airflow
limits are set, touch SAVE, to see ZONING CHECKOUT menu.
6.4.8.2. Damper/Sensor Check
The Sensor/Damper Check allows the installer to check each zone damper for operation, as well
as insure the zone sensor corresponds to that particular zone. When first initiated, the Zone 1
damper will fully open, and all other zones will close. Using the Left (<) or Right (>) buttons,
the installer can select each zone and verify the damper is fully open while all other dampers
remain closed.
37