Motor Lubrication; Control; Emergency Stop Device - J. D. NEUHAUS PROFI 6 TI Customer's Operating And Assembly Instructions

Hide thumbs Also See for PROFI 6 TI:
Table of Contents

Advertisement

3.5.5. Motor lubrication

The JDN high performance grease contained in
the motor allows for operation with oil-free com-
pressed air.
It works over an operating time of about 250 hours
and should, however, be replaced as required, but
after five years at the latest.

3.5.6. Control

CAUTION
Danger of Burns
Burns may occur when touching metallic hand
valves that are hotter than 43 C (109 F).
Wear protective gloves.
CAUTION
Danger of frostbite
Frostbite may occur when touching metallic hand
valves that are colder than 0 C (32 F).
Wear protective gloves.
With E-control (
Figure 5), you can control the
movements via push buttons. The directions of
movement are marked on the top of the valve
housing.
Figure 5: Control
The control system is suitable for use in explosive
areas.
Doc.-No.: VA057988-10-OM-EN-0821-62-1
P
RODUCT INFORMATION
All control switches automatically return to the
neutral position when released. All movements are
stopped instantaneously and the load is securely
held in its current position.

3.5.7. EMERGENCY STOP device

Your control system is equipped with an EMER-
GENCY STOP device.
By pressing the red EMERGENCY STOP button,
a separate blocking valve closes and your product
PROFI 6 TI instantly comes to a halt and the load
is held securely in its current position. The control
system is now inoperable.
Page 15 of 62

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P706448

Table of Contents