Table of Contents

Advertisement

No.
Menu Items
11
Protect Code clear
SP7-1: Factory settings clear
This resets all SP and User tool settings except for the following SP and User tool numbers.
• User tool 1: Counter Display (Masters and Prints)
• User tool 2-4: mm/inch
• User tool 2-5: Language on LCD
• User tool 2-6: Date/Time
• SP2-4: Destination code
• SP2-20: Destination setting
• SP2-80: Auto off at unusual voltage
• SP3-3: Input serial number
• SP6-All: Adjustments
SP7-3: Total counter clear
This resets the following SP numbers
• SP1-1 Total master counter
• SP1-20 Total print counter
• The counters for "User tool 1: Counter Display" are unresettable counters
SP7-11: Protect Code clear
This clears the settings of the "User Tools Protect (Administrator Setting)".
• User Tools Protect: Off
• User Tools Protect PW (Password): null

8. System Test

SP Table (SP 8-xxx)
No.
Menu Items
1
Download main firmware
2
Upload main firmware
Default
Settings
-
Start with # key
-
Start with # key
Service Program Mode
6
45