③ C onnect wires from X and Y terminals of R/C to X and Y terminals of indoor unit. R/C
wires (X, Y) have no polarity. Fix wires such that the wires will run around the terminal
screws on the top case of R/C.
④ Install the upper case with care not to pinch wires of R/C.
Cautions for wire connection
Use wires of no larger than 0.5 mm
through the remote control case. Take care not to
pinch the sheath.
Tighten by hand (0.7 N·m or less) the wire connection.
If the wire is connected using an electric driver, it may
cause failure or deformation.
In case of exposing wiring
(When the wiring is taken out from the "upper center"
or "upper left" of R/C)
① Cut out the thin wall sections on the cases for the size of wire.
When taking the wiring out from the upper center, open a hole before separating the upper and bottom cases. This will reduce risk of
damaging the PCB and facilitate subsequent work.
When taking the wiring out from the upper left, take care not to damage the PCB and not to leave any chips of cut thin wall inside.
Upper center
上面中央の場合
上ケース
② F ix the bottom R/C case on a flat surface with two wood
screws.
③ In case of the upper center, pass the wiring behind the
bottom case. (Hatched section)
④ C onnect wires from X and Y terminals of R/C to X and Y
terminals of indoor unit. R/C wires (X, Y) have no polarity.
Fix wires such that the wires will run around the terminal
screws on the top case of R/C.
⑤ I nstall the top case with care not to pinch wires of R/C.
⑥ Seal the area cut in ① with putty.
2
for wiring running
上面左の場合
下ケース
上面中央の場合
Upper left
上面左の場合
Upper case
上ケース
190 mm
120mm
(for retrieving
120 mm
左側の場合
190mm
wire from upper
(for retrieving wire
中央の場合
center)
from upper left)
41
-
-
ブッ シ ング
50
8
'17 • PAC-T-257
200
Wiring hole on
下ケース配線穴
bottom case
Bottom case
下ケース
パテで シール
する こ と
リ モコ ン配線