Mitsubishi Heavy Industries SRK100VNXPZSX Technical Manual page 28

Table of Contents

Advertisement

SRK125VNXPZSX
Model
Cooling Mode
Outdoor
18˚CDB
21˚CDB
air temp.
12˚CWB
14˚CWB
˚CDB
TC
SHC
TC
SHC
11
13
15
17
19
21
23
11.19 8.68 12.05 8.52 12.88 9.10 13.27 9.02 13.71 8.95 14.58 9.35 15.45 9.14
25
27
11.14 8.65 12.05 8.52 12.91 9.11 13.30 9.03 13.70 8.95 14.49 9.31
29
11.05 8.61 11.88 8.45 12.70 9.03 13.10 8.95 13.51 8.88 14.31 9.25
31
10.95 8.56 11.71 8.37 12.49 8.94 12.90 8.87 13.31 8.80 14.13 9.19
33
10.26 8.05 10.73 8.46 11.53 8.29 12.29 8.86 12.70 8.80 13.11 8.73 13.94 9.12
35
9.71 7.77 10.39 8.30 11.36 8.22 12.08 8.77 12.50 8.72 12.92 8.65 13.76 9.06
37
9.60 7.72 10.22 8.22 11.15 8.12 11.86 8.68 12.26 8.62 12.67 8.56 13.47 8.96
39
9.48 7.66 10.05 8.14 10.94 8.03 11.64 8.59 12.03 8.53 12.41 8.46 13.18 8.86
41
9.36 7.60 9.89 8.07 10.74 7.95 11.42 8.51 11.79 8.44 12.16 8.37 12.89 8.77
43
9.25 7.54 9.72 7.99 10.53 7.86 11.21 8.42 11.55 8.35 11.90 8.28 12.60 8.67
SRK125VSXPZSX
Model
Cooling Mode
Outdoor
18˚CDB
21˚CDB
air temp.
12˚CWB
14˚CWB
˚CDB
TC
SHC
TC
SHC
11
13
15
17
19
21
23
25
11.19 8.68 12.05 8.52 12.88 9.10 13.27 9.02 13.71 8.95 14.58 9.35 15.45 9.14
27
11.14 8.65 12.05 8.52 12.91 9.11 13.30 9.03 13.70 8.95 14.49 9.31
29
11.05 8.61 11.88 8.45 12.70 9.03 13.10 8.95 13.51 8.88 14.31 9.25
31
10.95 8.56 11.71 8.37 12.49 8.94 12.90 8.87 13.31 8.80 14.13 9.19
33
10.26 8.05 10.73 8.46 11.53 8.29 12.29 8.86 12.70 8.80 13.11 8.73 13.94 9.12
35
9.71 7.77 10.39 8.30 11.36 8.22 12.08 8.77 12.50 8.72 12.92 8.65 13.76 9.06
37
9.60 7.72 10.22 8.22 11.15 8.12 11.86 8.68 12.26 8.62 12.67 8.56 13.47 8.96
39
9.48 7.66 10.05 8.14 10.94 8.03 11.64 8.59 12.03 8.53 12.41 8.46 13.18 8.86
41
9.36 7.60
9.89 8.07 10.74 7.95 11.42 8.51 11.79 8.44 12.16 8.37 12.89 8.77
9.25 7.54
9.72 7.99 10.53 7.86 11.21 8.42 11.55 8.35 11.90 8.28 12.60 8.67
43
Notes (1) These data show average statuses.
Note(1)))
Depending on the system control, there may be ranges where the operation is not conducted continuously.
Note(1)))
These data show the case where the operation frequency of a compressor is fixed.
(2) Capacities are based on the following conditions.
Note(1) )
Corresponding refrigerant piping length :7.5m
Note())))
)Level difference of Zero.
(3) Symbols are as follows.
Note())))
TC : Total cooling capacity (kW)
Note( ))))
SHC : Sensible heat capacity (kW)
Note(1)))
HC : Heating capacity (kW)
Indoor unit
SRK60ZSX-S (2 units)
Indoor air temperature
23˚CDB
26˚CDB
27˚CDB
16˚CWB
18˚CWB
19˚CWB
TC
SHC
TC
SHC
TC
10.41 7.80 11.05 8.36 11.37 8.28 11.72 8.21 12.42 8.61 13.12 8.42
10.79 7.97 11.46 8.52 11.79 8.44 12.16 8.37 12.91 8.77 13.65 8.58
11.16 8.13 11.87 8.69 12.22 8.61 12.61 8.54 13.39 8.93 14.17 8.74
11.54 8.30 12.27 8.85 12.64 8.77 13.05 8.70 13.87 9.10 14.69 8.90
11.80 8.41 12.55 8.96 12.93 8.89 13.34 8.81 14.18 9.21 15.02 9.00
12.05 8.52 12.83 9.08 13.21 9.00 13.64 8.93 14.49 9.31 15.34 9.11
12.05 8.52 12.85 9.09 13.24 9.01 13.67 8.94 14.54 9.33 15.40 9.13
Indoor unit
SRK60ZSX-S (2 units)
Indoor air temperature
23˚CDB
26˚CDB
27˚CDB
16˚CWB
18˚CWB
19˚CWB
TC
SHC
TC
SHC
TC
10.41 7.80 11.05 8.36 11.37 8.28 11.72 8.21 12.42 8.61 13.12 8.42
10.79 7.97 11.46 8.52 11.79 8.44 12.16 8.37 12.91 8.77 13.65 8.58
11.16 8.13 11.87 8.69 12.22 8.61 12.61 8.54 13.39 8.93 14.17 8.74
11.54 8.30 12.27 8.85 12.64 8.77 13.05 8.70 13.87 9.10 14.69 8.90
11.80 8.41 12.55 8.96 12.93 8.89 13.34 8.81 14.18 9.21 15.02 9.00
12.05 8.52 12.83 9.08 13.21 9.00 13.64 8.93 14.49 9.31 15.34 9.11
12.05 8.52 12.85 9.09 13.24 9.01 13.67 8.94 14.54 9.33 15.40 9.13
Outdoor unit
FDC125VNX
28˚CDB
31˚CDB
20˚CWB
22˚CWB
SHC
TC
SHC
TC
SHC
Outdoor unit
FDC125VSX
28˚CDB
31˚CDB
20˚CWB
22˚CWB
SHC
TC
SHC
TC
SHC
27
-
-
'17 • PAC-T-257
Heating Mode:HC
(kW)
Indoor air temperature
Outdoor
air temp.
33˚CDB
˚CDB ˚CWB
24˚CWB
16
-19.8 -20
9.12 9.05
TC
SHC
-17.7 -18
9.67 9.60
-15.7 -16
10.23 10.15 10.07 9.98 9.90
-13.5 -14
10.67 10.59 10.50 10.42 10.33
-11.5 -12
11.11 11.03 10.94 10.85 10.76
-9.5
-10
11.56 11.47 11.38 11.29 11.19
-7.5
-8
12.00 11.91 11.82 11.72 11.62
-5.5
-6
12.49 12.40 12.30 12.20 12.10
-3.0
-4
12.99 12.89 12.79 12.68 12.57
-1.0
-2
13.48 13.38 13.27 13.16 13.05
1.0
0
13.98 13.87 13.76 13.64 13.52
2.0
1
14.22 14.11 14.00 13.88 13.76
3.0
2
14.22 14.11 14.00 13.88 13.76
5.0
4
14.22 14.11 14.00 13.88 13.76
7.0
6
14.22 14.11 14.00 13.88 13.77
9.0
8
14.81 14.70 14.59 14.47 14.35
11.5
10
15.41 15.29 15.18 15.06 14.94
13.5
12
16.22 16.09 15.97 15.85 15.90
15.5
14
17.03 16.90 16.76 16.65 16.86
16.5
16
17.44 17.30 17.16 17.04 17.34
Heating Mode:HC
(kW)
Indoor air temperature
Outdoor
air temp.
33˚CDB
˚CDB ˚CWB
24˚CWB
16
-19.8 -20
14.11 14.00 13.89 13.78 13.66
TC
SHC
-17.7 -18
14.17 14.06 13.94 13.83 13.72
-15.7 -16
14.23 14.11 14.00 13.89 13.77
-13.5 -14
14.23 14.11 14.00 13.89 13.77
-11.5 -12
14.22 14.11 14.00 13.89 13.77
-9.5
-10
14.22 14.11 14.00 13.89 13.77
-7.5
-8
14.22 14.11 14.00 13.89 13.77
-5.5
-6
14.22 14.11 14.00 13.88 13.77
-3.0
-4
14.22 14.11 14.00 13.88 13.77
-1.0
-2
14.22 14.11 14.00 13.88 13.76
1.0
0
14.22 14.11 14.00 13.88 13.76
2.0
1
14.22 14.11 14.00 13.88 13.76
3.0
2
14.22 14.11 14.00 13.88 13.76
5.0
4
14.22 14.11 14.00 13.88 13.76
7.0
6
14.22 14.11 14.00 13.88 13.77
9.0
8
14.81 14.70 14.59 14.47 14.35
11.5
10
15.41 15.29 15.18 15.06 14.94
13.5
12
16.22 16.09 15.97 15.85 15.90
15.5
14
17.03 16.90 16.76 16.65 16.86
16.5
16
17.44 17.30 17.16 17.04 17.34
(kW)
˚CDB
18
20
22
24
8.97 8.90 8.83
9.52 9.44 9.37
PCA001Z629
(kW)
˚CDB
18
20
22
24
PCA001Z629

Advertisement

Table of Contents
loading

Table of Contents