Technical Data

This cooker is designed for use on either :-
NATURAL GAS (Cat I2H ) at 20mbar or LP GAS (Cat I3+ ) Butane 29mbar / Propane 37mbar.
NB: THE NATURAL GAS AND LP GAS VERSIONS OF THESE COOKERS ARE DIFFERENT MODELS
AND CANNOT BE CONVERTED FROM ONE GAS FAMILY TO THE OTHER
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION :
Country of Destination: GB
Gas
Natural Gas
Butane
Propane
(See appliance data badge for test pressures)
Dimensions
Minimum space above hotplate
Connections
Gas:
Rp
1
/
at rear right-hand side
2
Ratings
Hotplate
Right hand High burner
Large Burner
Medium Burners
Small Burner
Ovens
Grill
Gas burner inputs based on Gross Calorifi c Value
Warmer
LOWER RIGHT HAND COOKER UPRIGHT (Remove storage drawer)
Electric
20mbar
220 - 240V 50Hz
29mbar
37mbar
Overall height
minimum 893mm
Overall width
1100mm See 'Positioning of Cooker'
Overall depth
648mm
Space for fixing
See 'Positioning of Cooker'
650mm
Electric
220 - 240V 50Hz
Natural Gas
3.0kW
3.0kW
1.7kW
1.0kW
3.2kW
2.73kW
160W
L.P. Gas
Injector
128
3.0kW (210g/h)
134
3.0kW (210g/h)
109
1.7kW (119g/h)
75
1.0kW (70g/h)
237
2.9kW (224g/h)
190
2.73kW (192g/h)
35
maximum 920mm
Injector
87
87
68
51
85
85

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Toledo 110 gas