QSFP+ Ports

Installing a QSFP+ Module
1. Remove the safety cap from the module and pull the locking lever into the down 
(unlocked) position.
2. Insert the QSFP+ module into the switch QSFP+ port until it clicks into place. Use 
minimal pressure when you insert the module into the port. Do not use excessive 
force when you insert the module; you can damage the module or the QSFP+ port.
3. Pull up the locking lever to lock the module into place.
4. Connect the fiber‐optic cable.
Connecting a Fiber Optic Cable
© Copyright Lenovo 2017
The QSFP+ ports accept supported QSFP+ modules. The QSFP+ module provides 
an MTP cable connector for connecting to external devices.
To install a QSFP+ module in a QSFP+ port on the switch, complete the following 
steps.
Note: To avoid damage to the cable or the QSFP+ module, do not connect the cable 
before the QSFP+ module is installed in the switch port.
The module has a mechanical guide key to prevent you from inserting the 
module incorrectly.
Attention: To avoid damage to the fiber optic cables, follow these guidelines:
Do not route the cable along a folding cable‐management arm.
When you attach the cable to a device on slide rails, leave enough slack in the 
cable so that it does not bend to a radius of less than 38 mm (1.5 in.) when the 
device is extended or become pinched when the device is retracted.
Route the cable away from places where it can be snagged by other devices in 
the rack.
Do not overtighten the cable straps or bend the cables to a radius of less than 38 
mm (1.5 in.).
Do not put excess weight on the cable at the connection point. Make sure that the 
cable is well supported.
Chapter 2: Installing and Removing the CN4093
29