External oscillator unit for rf power supply (21 pages)
Summary of Contents for Ulvac DC-5-P
Page 1
DC0048e-04 DC Pulse Power Supply 5kW/10kW model:DC-5-P/DC-10-P 4th version, Mar, 2023 ULVAC, Inc. Components Division Before using this product, be sure to read it. Also, keep this manual at hand with care...
Page 2
The copyrights of the operation manual and this safety guide belong to ULVAC, Inc. Components Division. A part and whole part of this operation manual are prohibited to copy without a permit of ULVAC, Inc.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 INTRODUCTION 1. Precautious points on safety Major part of the accidents occurs in relation to the operation carelessly conducted by the operator, the inspection/service and the repair work. Also, if you do not observe the basic caution matters on safety and neglect the dangerous preperception, it is easy to occur.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 INTRODUCTION 2. Safety symbol marks In this operation manual and the warning display of the product main body, the symbol marks about the safety in order to understand the matters to be observed are being put up.
Page 5
DC Pulse Power Supply 【DC-5-P/DC-10-P】 INTRODUCTION 2-2 Safety symbol marks on the unit main body The following safety symbol marks are placed on the unit main body. List of safety symbol marks Safety symbol marks Description Heavy loads ・There is a danger of getting injury.
Page 6
DC Pulse Power Supply 【DC-5-P/DC-10-P】 INTRODUCTION Safety symbol marks Description High temperature heated part ・Do not touch, or you may get burned. Use copper conductors only. The connector part shall not be lifted. Otherwise it may be damaged. Do not hold and lift the connector.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 INTRODUCTION 3. About this product The sentences and illustrations in this operation manual are based on the information at the time of this operation manual prepared. This operation manual may be subject to change without prior notice. Since these changes give the influence on the inspection, confirm the latest information in our company’s...
DC Pulse Power Supply 【DC-5-P/DC-10-P】 INTRODUCTION 7.Others If there is a document describing the individual contract or specification aside from this manual, the rules described in these documents are observed. For the questions and consultation on the product, please check the model and production number, and make an inquiry at a service office, agent, or our standard product division.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 INTRODUCTION 6. About responses to RoHS The following 10 specified environmentally hazardous chemical substances regulated by the RoHS Directive are not contained in the main body and the cable assembly attached as standard above t he threshold (Revised RoHS Directive 2011/65 / EU and (EU) 2015 / 863).
3-2-3. How to install ............................... 14 3-2-4 About clearance ............................15 3-3. W ....................16 IRING AND CONNECTING 3-3-1. Cables connected to DC-5-P/10-P ....................16 3-3-2. USER IO PORT process cable ......................16 3-4. S ............... 17 TRUCTURE OF AND PULSE SYNCHRONOUS 3-4-1.
Page 11
DC Pulse Power Supply 【DC-5-P/DC-10-P】 Table of Contents 3-4-6. About settings for pulse synchronization system ..............20 3-4-7. Startup input sequence in M/S operation / pulse-synchronized operation ....21 3-5......................23 PROTECTION SHEETS 4. DESCRIPTION OF FUNCTIONS ........24 4-1.
Page 12
DC Pulse Power Supply 【DC-5-P/DC-10-P】 Table of Contents 5-3. D ..................63 IGITAL CONNECTION CIRCUIT 6. MAINTENANCE ............... 64 6-1. M ............64 AINTENANCE NSPECTION OF THIS POWER SUPPLY 6-2. A ..............65 BOUT RECOMMENDED REPLACEMENT PARTS 7. TROUBLESHOOTING ............. 66 7-1.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 1 FOR YOUR SAFETY USE 1.FOR YOUR SAFETY USE In order to use this unit in a safe manner, we describe the caution points on safety, the attached position of warning labels and the contact party.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 1 FOR YOUR SAFETY USE 1-2 Warning label / Name plate affixing position REFERENCE The affixing position of warning labels is shown in the appendix "External View" in Chapter 8. Keep these warning labels clean at all times so that all of them are legible. Use cloth and water for the cleaning of the warning labels.
■ Maximum six units can be connected in master-slave manner (hereinafter referred to as "M/S"). (*An M/S cable (option) is required). (*DC-5-P and DC-10-P cannot be connected in the M/S manner. M/S is available only for the same models). ■ On the front panel, each parameter, such as the oscillating frequency, can be set.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 2 OVERVIEW 2-3. Composition This power supply consists of the parts below. Power main unit: [Standard accessory] D-Sub connector for USER IO PORT (product of JAE: DC-C4-J12-F1/DC-37Pf-N): 1 set M/S setting insulation driver: Instruction Manual: [Option] AC input cable (Cable length: 1m, 2m, 4m, 6m, 8m, 10m)...
DC Pulse Power Supply 【DC-5-P/DC-10-P】 2 OVERVIEW 2-4. Specifications 2-4-1. Electrical specification Table 2-1: Electrical specification Item Specifications Type DC-5-P DC-10P Rated input voltage AC208V AC208V Input voltage AC187V~229V variation range Number of phases / 3 phase: 50/60 Hz Frequency...
DC Pulse Power Supply 【DC-5-P/DC-10-P】 2 OVERVIEW 2-4-2. Physical Specifications Table 2-2: Other specifications Item Specifications Cooling method Forced air cooling system Outer dimensions 483mm(W)×630mm(D)×133mm(H)* No protrusions included. Mass DC-5-P:29kg DC-10-P:36kg Usage environment Indoor use at 1,000m or less above sea level without direct sunlight and corrosive gas.
Page 19
DC Pulse Power Supply 【DC-5-P/DC-10-P】 2 OVERVIEW Table 2-3: Inversion pulse width by oscillating frequency (5kHz to 150 kHz: In the unit of 1 kHz) Oscillating Minimum Maximum Minimum Maximum frequency inversion pulse inversion pulse V LIMIT[V] Duty ratio [%]...
Page 20
DC Pulse Power Supply 【DC-5-P/DC-10-P】 2 OVERVIEW Oscillating Minimum Maximum Minimum Maximum frequency inversion pulse inversion pulse V LIMIT[V] Duty ratio [%] Duty ratio [%] [kHz] width [μs] width [μs] 25.5 26.0 26.5 27.0 27.5 28.0 28.5 29.0 29.5 30.0 30.5...
Page 21
DC Pulse Power Supply 【DC-5-P/DC-10-P】 2 OVERVIEW Oscillating Minimum Maximum Minimum Maximum frequency inversion pulse inversion pulse V LIMIT[V] Duty ratio [%] Duty ratio [%] [kHz] width [μs] width [μs] 40.4 39.9 40.3 39.8 40.2 39.6 40.0 39.4 39.8 39.1 39.5...
Page 22
DC Pulse Power Supply 【DC-5-P/DC-10-P】 2 OVERVIEW Oscillating Minimum Maximum Minimum Maximum frequency inversion pulse inversion pulse V LIMIT[V] Duty ratio [%] Duty ratio [%] [kHz] width [μs] width [μs] 39.4 39.7 38.6 38.9 39.2 39.5 39.8 38.6 38.9 39.2 39.4...
In addition, select a suitable cable ground based on the line shape of the wiring material selected. 相 相 相 Figure 2-2. Assignment of input connector at the product side(Upper:DC-5-P Lower:DC-10-P) Table 2-5. HARTING connector configuration at the cable side of input section(5-P) Name Model Q’ty...
In addition, select a suitable cable ground based on the line shape of the wiring material selected. Figure 2-3. Assignment of output connector at the product side(Common to DC-5-P and DC-10-P) Table 2-9. HARTING connector configuration at the cable side of output section...
DC Pulse Power Supply 【DC-5-P/DC-10-P】 3 PREPARATION 3. PREPARATION We describe necessary preparation and caution matters in step where after this unit is delivered at your hand, you use this unit. 3-1.Unpacking When unpacking, check the following items. 1) Check that there are no flaws or dents.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 3 PREPARATION Substrate Φ3 AC input 187~ 229V DC Pulse Power supply DC Power Supply Φ3 AC input Output cable M/S cable 187~ 229V DC Pulse Power supply CATHODE ANODE EARTH EARTH Earth cable System ground...
DC Pulse Power Supply 【DC-5-P/DC-10-P】 3 PREPARATION 3-2-4 About clearance In the power supply unit, the air-intake section is placed on the front face while the air-discharge section is placed on the back face. Pay special attention to the clearance between the front face and the back face.
We recommend you to use our optional supplies. For our optional products, refer to [Table 3-1. Processing of optional input cable terminal(DC-5-P)] and [Table 3-2. Processing of optional input cable terminal(DC-10-P)] and [Table 3-3. Processing of optional output cable terminal].
3-4-1. About M/S system configurations With several power supply units connected with M/S cables, you can use it as a M/S system. A system including maximum six units (DC-5-P: 5 to 30kW; DC-10-P: 10kW to 60kW) can be formed. (*DC-5-P and DC-10-P cannot be connected in the M/S manner. M/S is available only for the same models).
DC Pulse Power Supply 【DC-5-P/DC-10-P】 3 PREPARATION 3-4-2. Name definition of power supply with M/S connected The name of each power supply with M/S connected is as shown in Table 3-4. Table 3-4: Name of each power supply with M/S connected...
DC Pulse Power Supply 【DC-5-P/DC-10-P】 3 PREPARATION 3-4-5. About pulse synchronization system The reverse-pulses of multiple systems can be synchronized by using pulse synchronization optical cables. To achieve the synchronization, you are required to connect the pulse synchronization optical cable and set up the power supply unit.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 3 PREPARATION 3-4-6. About settings for pulse synchronization system For pulse synchronization, the settings need to be made in power supply in addition to establishment of connection between optional optical synchronization cables. For the operation/settings, see below.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 3 PREPARATION 3-4-7. Startup input sequence in M/S operation / pulse-synchronized operation If you start the system in the M/S configuration, turn on all the power supplies at the same time or turn on the power supply from the slave.
Page 34
DC Pulse Power Supply 【DC-5-P/DC-10-P】 3 PREPARATION For a pulse synchronization system, start it from System 1 (the upstream system). If the downstream system is started first, ERROR appears. The display of "ERROR “disappears by entering the reset signal after all the electric powers are activated.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 3 PREPARATION Table 3-5: DC startup sequence in M/S / optical synchronization mode Configuration Startup sequence From the downstream slave System optical synchronization From System 1 3-5.protection sheets On the top plate, a protection sheet is covered for the contamination prevention. For this part, remove the sheet.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 4 DESCRIPTION OF FUNCTIONS 4. DESCRIPTION OF FUNCTIONS This section describes various functions of this power supply. 4-1. Name and function of each part 4-1-1. DC power front panel ① ⑫ ⑥ ④ ⑤ ⑦...
Page 37
DC Pulse Power Supply 【DC-5-P/DC-10-P】 4 DESCRIPTION OF FUNCTIONS Name Shape Function Set output values, output values, and various parameters appear. ⑫ Display OLED display LED (Green) This lights up when the output reaches the set value. ⑬ SETPOINT LED (Green)
① ⑩ ④ ⑪ ⑫ ⑬ ③ ② ⑥ ⑤ ⑤ Figure 4-2: Back of Power Unit (Upper:DC-5-P Lower:DC-10-P) Table 4-2: Name and function on back of power unit Name Shape Function Connector for AC input ① AC INPUT Connector ②...
DC Pulse Power Supply 【DC-5-P/DC-10-P】 4 DESCRIPTION OF FUNCTIONS 4-2. Description of each operation mode This power supply can be used in the following operation modes. The control mode is switched on the front panel or using commands via the SERIAL communication port.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 4 DESCRIPTION OF FUNCTIONS 4-2-2-1. Pin allocation of USER IO PORT The pin allocation in the USER control mode is as follows. For the USER control, connect to external control devices including a PLC in reference to "Table 5-6: USER control signal connecting equivalent circuit."...
ISET :the output is produced by the current control. *1 The output setting in power control can be set in the unit of 0.01 kW for the DC-5-P/D C-10-P single unit. For M/S connection, the output setting can be done in the unit of 0.1 kW.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 4 DESCRIPTION OF FUNCTIONS 4-4. About each monitor signal and LEVEL signal in system configuration The rated voltage value against each monitor signal (VOUT, IOUT, POUT) and LEVEL signal varies depending on the power system configuration. See the table below.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 4 DESCRIPTION OF FUNCTIONS 4-6. Description of PULSE PARAM function Pulse parameter can switch between two predetermined types (SET A or SET B) of oscillation frequencies, inversion pulse widths, ARC parameters depending on your application purpose.
Page 44
DC Pulse Power Supply 【DC-5-P/DC-10-P】 4 DESCRIPTION OF FUNCTIONS Table 4-11: Factory default settings of initial pulse parameter values MENU screen hierarchy 100KHz 100KHz Left-Lower in main screen Center-Lower in main screen MENU/CNFG/ARC/PULS/PARC/1st MENU/CNFG/ARC/PULS/PARC/2nd 100us 100us MENU/CNFG/ARC/PULS/PARC/ENBL ⇔ 0.2ms 0.2ms...
DC Pulse Power Supply 【DC-5-P/DC-10-P】 4 DESCRIPTION OF FUNCTIONS 4-7. Description of oscillation mode function The oscillation mode includes: Continuous mode; One-pulse mode; and DC mode. ・Continuous mode Outputs specified frequency and inversion pulse width. The charge-up of the target is controlled by producing the reverse-pulse output continuously.
Page 46
DC Pulse Power Supply 【DC-5-P/DC-10-P】 4 DESCRIPTION OF FUNCTIONS In the continuous and one-pulse modes, following parameters are retained independently. If the following parameters are changed, only the changes in the oscillation mode parameter of the pulse parameter currently selecting are reflected.
Page 47
DC Pulse Power Supply 【DC-5-P/DC-10-P】 4 DESCRIPTION OF FUNCTIONS Selecting the one-pulse mode. Continuous mode One-pulse mode Pulse parameter Pulse parameter PARAMETER MENU/CNFG/ARC/PULS/PARC/1st MENU/CNFG/ARC/PULS/PARC/2nd MENU/CNFG/ARC/PULS/PARC/ENBL 100us 100us 100us 100us Changing the PARC/2nd from 8 us to 10 us Continuous mode...
DC Pulse Power Supply 【DC-5-P/DC-10-P】 4 DESCRIPTION OF FUNCTIONS 4-8. Selection of oscillation mode The setting procedure for the selection of each oscillation mode depends on the each operation mode (LOCAL, USER, HOST). 4-8-1. Setup in LOCAL Selectable on the main screen. It can be selected by changing an item at the lower right on the screen.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 4 DESCRIPTION OF FUNCTIONS 4-9. Description of inter-pulse ARC function In the continuous mode, if an ARC is detected while the reverse pulse operation is not working, the ARC is erased by outputting the reverse pulse.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 4 DESCRIPTION OF FUNCTIONS Interruption time ② Interruption time ① Interruption time ② Interruption time ① 電圧 Voltage 2nd effective time (PARC/ENBL) occurred occurred occurred occurred 電流 Current Time: t t 時間 Description of interruption effective time at the 2nd and the subsequent points Figure 4-9: Image of waveform of inter-pulse ARC extinguishing function 4-10.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 4 DESCRIPTION OF FUNCTIONS 4-11. Description of Ramp time function 4-11-1. Ramp time function① Setting the ramp time function ① allows you to adjust the time necessary to reach the command value, the ramp start value, etc.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 4 DESCRIPTION OF FUNCTIONS 4-11-2. Ramp time function② By setting the ramp time function ②, only the time to reach the command value can be adjus ed.Unlike the ramp time function ①, it accepts changes in the command value while the output is ON.
LEVEL OVER ERROR E60* This occurs when a command voltage and an overcurrent. This occurs when M/S consists of DC-5-P and DC-10-P PCB SETTING ERROR E70* specifications. * is the power supply number corresponding to M/S. (See Table 4-16.)
DC Pulse Power Supply 【DC-5-P/DC-10-P】 4 DESCRIPTION OF FUNCTIONS Table 4-16: Correspondence table of error and warning codes Number of connected units Name Number of * 1st unit Master 2nd unit Slave1 ・ ・ ・ ・ ・ ・ ・ ・...
DC Pulse Power Supply 【DC-5-P/DC-10-P】 4 DESCRIPTION OF FUNCTIONS 4-14. Screen lock function The screen can be locked in order to avoid switching from the Start screen even pressing the button on the front face. If you would like to lock or release, contact the store of purchase.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 5 HOW TO OPERATE 5. HOW TO OPERATE This section describes how to operate and handle this power supply. 5-1. How to operate in LOCAL mode This section describes the power operation in the LOCAL mode.
Page 57
DC Pulse Power Supply 【DC-5-P/DC-10-P】 5 HOW TO OPERATE :If the oscillation mode is the continuous mode, the oscillating frequency is displayed. In the F one-pulse or DC mode, 0kHz is displayed. :In the continuous or one-pulse mode, the set inversion pulse width is displayed.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 5 HOW TO OPERATE 5-1-2. Parameter tree in MENU screen After that, carry out the operation using various buttons on the front panel. For the menu hierarchy, see the parameter tree below. Figure 5-1 DC-5-P/10-P Parameter Tree...
DC Pulse Power Supply 【DC-5-P/DC-10-P】 5 HOW TO OPERATE 5-1-3. About buttons on front panel * For the button arrangement, see Fig. 4-1 and Table 4-1. RESET MENU ERROR ・DC ON/OFF button In the state where READY and INTERLOCK OK light up, pressing the DC ON button starts the DC output.
Page 60
DC Pulse Power Supply 【DC-5-P/DC-10-P】 5 HOW TO OPERATE * Example of changes on the main screen ◀ appears. Select the item to ENT button ◀▶ be changed by button. The setting item to ◀▶ be changed blinks. button ENT button Make changes to the ◀▶...
DC Pulse Power Supply 【DC-5-P/DC-10-P】 5 HOW TO OPERATE 5-1-4. About MENU screen ・Press the MENU button to display the menu screen. The current hierarchy is displayed in the first line and the selected items in the second line. CNFG: this is used to change various parameters.
Page 62
The setup is carried out in the M/S. ※This setting is available only to the master device. The number of connected power supply units is specified. DC-5-P and DC-10-P cannot be connected. For both 5-P and 10-P, maximum 6 units can be specified.
Page 63
DC Pulse Power Supply 【DC-5-P/DC-10-P】 5 HOW TO OPERATE POWR: this enables one to change the limit value of the output power. 10-P: Selectable from 0 to (αx10) kW depending on the number of power supply units connected. * α:The number of units using the 10kW 5-P: Selectable from 0 to (βx5) kWA depending on the number of power supply units...
Page 64
DC Pulse Power Supply 【DC-5-P/DC-10-P】 5 HOW TO OPERATE PARC: The inter-pulse ARC processing setting can be changed. 1ST: The first shutdown time for the inter-pulse ARC can be changed. The second and the following shutdown time for the inter-pulse ARC can be changed.
Page 65
DC Pulse Power Supply 【DC-5-P/DC-10-P】 5 HOW TO OPERATE CONT: Inter-pulse ARC generating times for shifting into HARD ARC processing can be changed. If the inter-pulse ARC is generated for the number of times specified during JDGE TIME, it shifts into the HARD ARC.
Page 66
DC Pulse Power Supply 【DC-5-P/DC-10-P】 5 HOW TO OPERATE SETP:this enables one to change the judgment criterion of SETPOINT. The settable range is 2 to 8% in steps of 1%. HOST:this enables one to change the settings in the SERIAL communication mode.
Page 67
DC Pulse Power Supply 【DC-5-P/DC-10-P】 5 HOW TO OPERATE BUS:This displays the current input bus voltage. The current input bus voltage is displayed. ARC :this displays the number of times that hard arcs are detected. The number of times that HARD ARC is detected is displayed.
Page 68
DC Pulse Power Supply 【DC-5-P/DC-10-P】 5 HOW TO OPERATE RMP2:this changes the rise time at the start of the output. With this ramp function, the rise time until the command value of the output can be adjusted. USE: Set ON/OFF of the ramp function.
Page 69
DC Pulse Power Supply 【DC-5-P/DC-10-P】 5 HOW TO OPERATE PULS: Synchronization of pulses can be specified. OSC: Validity/invalidity of the pulse synchronization function is selected. LINK: The number of units in pulse synchronization is specified. FORC: Selecting enable/disable of compulsion oscillation function.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 5 HOW TO OPERATE 5-1-5. Parameter list The changeable parameter list is shown below. Table 5-2: System parameter Variable Description Hierarchically Setting rage Unit Initial value width Select operation mode CNFG/SYTM/CONT LOCAL/USER/HOST ― ― USER...
Page 71
DC Pulse Power Supply 【DC-5-P/DC-10-P】 5 HOW TO OPERATE Table 5-3: Output parameter (limit value, ignition voltage, timer, etc.) Variable Description Hierarchically Setting rage Unit Initial value width CNFG/LIMT/POWR DC-10-P:0~(α×10) Setup of the limit value of Rated DC-5-P :0~(β×5.0) value*1 the output power.
Page 72
DC Pulse Power Supply 【DC-5-P/DC-10-P】 5 HOW TO OPERATE Table 5-4: Arc parameter (Detection of arc, Process-related parameters) Variable Initial Description Hierarchically Setting rage Unit width value Inter-pulse ARC From the inversion pulse usec CNFG/ARC/PULS/PARC Setup of first-time width currently specified to...
DC Pulse Power Supply 【DC-5-P/DC-10-P】 5 HOW TO OPERATE 5-2. How to operate in USER mode This section describes how to operate in the USER mode. In the USER mode, connecting the power supply with external control devices, such as a PLC, to exchange necessary information from USER IO PORT.
Page 74
DC Pulse Power Supply 【DC-5-P/DC-10-P】 5 HOW TO OPERATE Table 5-6: USER control signal connecting equivalent circuit Signal type Signal Equivalent circuit DC OFF※1 DC ON PULSE DC-5-P/10-P +15V PLC etc PARAM SEL AD INTERFACE side RESET PREG Digital input IREG 4.3kΩ...
DC Pulse Power Supply 【DC-5-P/DC-10-P】 5 HOW TO OPERATE 5-3. Digital I/O connection cir Digital I/O connection circuit is shown in Fig. 5-2. DC-5-P/10-P PLC? PLC etc. AD INTERFACE +15V Using the power supply's AUX ? ? ? AUX? ? ? ? ? ? ?
DC Pulse Power Supply 【DC-5-P/DC-10-P】 6 MAINTENANCE 6. MAINTENANCE We describe the contents of necessary maintenance in order to use this power supply for a long time. Ignorance of maintenance work accelerates wear-out of the unit and raises the probability of failure and malfunctioning 6-1.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 6 MAINTENANCE 6-2. About recommended replacement parts For a longer use of the power supply, we recommend periodical overhauls. See Table 6-1 which shows the recommended replacement parts. For an overhaul, be sure to contact us.
DC Pulse Power Supply 【DC-5-P/DC-10-P】 7 TROUBLESHOOTING 7. TROUBLESHOOTING This chapter describes how to take measures against trouble. 7-1. Troubleshooting In the event of a trouble, do the initial diagnosis according to the procedure below. If the symptom is not improved even after troubleshooting, contact us.
Page 79
If the command value electric voltage is within the stipulated value, and if the symptom repeats again, exchange the power supply unit. DC-5-P and DC-10-P cannot be mixed together Generates when 5-P and 10 are mixed and used in M/S.
DC Puse Power Supply 【DC-5-P/DC-10-P】 8 APPENDIX 8. APPENDIX The following documents about DC are attached. (1) External view of DC (2) China RoHS compliant (3) Operating instructions for serial communications Figure 8-1: External view of DC-5-P...
Page 81
DC Puse Power Supply 【DC-5-P/DC-10-P】 8 APPENDIX Figure 8-2: External view of DC-10-P...
Page 82
DC Puse Power Supply 【DC-5-P/DC-10-P】 8 APPENDIX 中华人民共和国中国电子行业标准SJ / T11364-2014 People's Republic of China Electronic Industry Standard SJ / T11364-2014 有毒有害物质或元素/ Hazardous substance 部件名称/Part name Cr6+ PBDE 印刷电路板/printed bord ○ ○ ○ ○ ○ ○ 电子零件/Electronic parts ○ ○ ○...
Page 83
DC Puse Power Supply 【DC-5-P/DC-10-P】 8 APPENDIX DC Pulse Power Supply 5kW/10kW model: DC-5-P/DC-10-P...
DC Puse Power Supply 【DC-5-P/DC-10-P】 8 APPENDIX 8-1. Overview of serial communications The DC-5-P/10-P power has a communications interface accessible from a serial port. This provides direct control from a host computer via serial communication. In addition, RS232C and RS485 are both available.
DC Puse Power Supply 【DC-5-P/DC-10-P】 8 APPENDIX 8-1-2. How to connect RS232C communication For DC, RXD has 2 pins and TXD has 3 pins. Connect to the HOST computer with a crossing cable. The cable connecting between HOST and DC shall be 10 m or less at the longest in length.
RESET MENU ERROR Figure 8-7 DC-5-P/10-P manual operation button ● How to set Address (1) First, press the MENU button on the front panel to display the MENU screen as shown below. (2) On the MENU screen, press the ◄ or ► button to select CNFG item on the screen and then press the ENT button.
Page 87
DC Puse Power Supply 【DC-5-P/DC-10-P】 8 APPENDIX ○ Communication rate setting The communication rate between DC and HOST computers. The initial value is set at 9600 bps. For a possible unstable communication state, such as due to a long wire length in RS485, it is recommended to decrease the communication rate.
8-2-1 Communication message packet DC-5-P/10-P communication message packets consist of the four types of fields as shown below. • Header field (SOF, each address, command + data field length information) • Command field (See the command list to be described later.) •...
Page 89
DC Puse Power Supply 【DC-5-P/DC-10-P】 8 APPENDIX Table 8-2 Message packet Header Field Command field Data field Checksum 0~7byte 2byte 1 byte Data transmitted in relation to the ・SOF 1byte command. XOR values of all data until ・Address 0x00~0xFF The length depends on the just before.
Page 90
DC Puse Power Supply 【DC-5-P/DC-10-P】 8 APPENDIX ● Checksum The checksum is the last field of a packet which is 1 byte. The content of this field is determined by the value of the information (the header field, command field, and data field) before the checksum.
DC Puse Power Supply 【DC-5-P/DC-10-P】 8 APPENDIX 8-3. Communication protocol The following shows the step of communication transactions between DC and HOST computer. HOST DC-5-P/10-P Message transmitting Message ACK/NAK receiving wating ACK/NAK transmitting ACK/NAK receiving Acknowledgment Acknowledgment Message wating Message transmitting...
Page 92
DC Puse Power Supply 【DC-5-P/DC-10-P】 8 APPENDIX (4) Acknowledgment message transmitted from DC DC judges whether it is a Write or Read command based on the incoming message. When receiving a Read command, DC collects required data and transmits a 1-byte command status + data as an acknowledgment message.
(0x13). Write command The commands below changes various parameters of DC or requests DC to executes specific operations. For setting parameters etc, see the instruction manual for DC-5-P/10-P. Table 8-4: Write command list Command...
Page 94
DC Puse Power Supply 【DC-5-P/DC-10-P】 8 APPENDIX Command Transmission data Acknowledgment data Command Command name Capacity Description Capacity Description Set the ignition voltage of the power supply. IGNITION 0x16 2byte 1byte STATUS VOLTAGE It can be set in the range from 800V to 1,500V in steps of 10V.
Page 95
DC Puse Power Supply 【DC-5-P/DC-10-P】 8 APPENDIX Command Transmission data Acknowledgment data Command Command name Capacity Description Capacity Description It is a setting of shutdown time for ARC processing in DC mode setting. Following values (fixed) can be selected for the shutdown time.
Page 96
DC Puse Power Supply 【DC-5-P/DC-10-P】 8 APPENDIX Command Transmission data Acknowledgment data Command Command name Capacity Description Capacity Description This is the command for setting PARC parameters. The following parameters are set at once. ○PARC_OSON_1ST_TIME The parameter of CNFG/ARC/PARC/1ST in the menu.
Page 97
DC Puse Power Supply 【DC-5-P/DC-10-P】 8 APPENDIX Command Transmission data Acknowledgment data Command Command name Capacity Description Capacity Description The frequency of in-between pulse ARC for shifting into the HARC ARC can be selected. PULSE HARC It can be set in the range between 2 and 5.
Page 98
DC Puse Power Supply 【DC-5-P/DC-10-P】 8 APPENDIX READ Command The following commands are for reading various parameters and the power status from DC. Table 8-5: READ command list Command Transmission data Acknowledgment data Command Command name Capacity Data content Capacity...
Page 99
DC Puse Power Supply 【DC-5-P/DC-10-P】 8 APPENDIX Command Transmission data Acknowledgment data Command Command name Capacity Data content Capacity Data content This sends back the output command value. The value to be sent back depends on the number of units to connect and the current output mode.
Page 100
DC Puse Power Supply 【DC-5-P/DC-10-P】 8 APPENDIX Command Transmission data Acknowledgment data Command Command name Capacity Data content Capacity Data content This sends back the status whether the Ramp operating function is ON or OFF. 0x9C RAMP ENABLE? 1byte 0x00 : DISABLE 0x01 : ENABLE The Ramp standup time set is responded.
Page 101
DC Puse Power Supply 【DC-5-P/DC-10-P】 8 APPENDIX Command Transmission data Acknowledgment data Command Command name Capacity Data content Capacity Data content The ARC detection voltage level set is responded. ARC SHUTDOWN 0xAB 2byte VOLTAGE? 40~500V 500 : 0x01F4 The ARC detection current level set is responded.
Page 102
DC Puse Power Supply 【DC-5-P/DC-10-P】 8 APPENDIX Command Transmission data Acknowledgment data Command Command name Capacity Data content Capacity Data content The parameter on the specified PARC is replied. The following parameters are collectively replied. ○PARC_1ST_TIME "PARC _1ST_TIME" set is transmitted. The value up to 20.0 (200) is transmitted.
Page 103
DC Puse Power Supply 【DC-5-P/DC-10-P】 8 APPENDIX An example of data transmission and reception is shown below ○Example of transmitting and receiving Write command For transmitting 10kW in command 0x12 (LEVEL signal setup) to the DC The Address settings of DC: for 25.
Page 104
DC Puse Power Supply 【DC-5-P/DC-10-P】 8 APPENDIX ○Example of transmitting and receiving Read command When inquiring the output power with the command "0x92" (output power inquiry) to DC. Setting of DC Address: Assumed it as "01." As an example of transmission and reception, the following data transmission and reception are carried out between the HOST side and the DC side.