INSTALLATION SITE

Vallox TSK Multi 50/80 MC must be installed in a location
where the temperature remains above +10°C. When the
unit is installed without a protective enclosure, the location
must be chosen so that its noise does not cause any
disturbance. Such locations include storage premises and
technical spaces.
Important! The whole length of the outdoor air duct to the unit
and exhaust air duct from the unit must be insulated using
closed cell insulation.
CONDENSING WATER
The delivery includes a water seal and an elbow for connecting the pipe that leads the water condensed from the extract air to the
floor drain (not directly into the sewer). The pipe must not rise after the water seal. See the accessory bag for further instructions
on the installation of the water seal and the elbow.
DIMENSION
TSK Multi 50
TSK Multi 80
mm
A
431
B
91
C
16
D
548
E
530
F
236
G
935
1060
H
900
1026
E
mm
519
91
16
SPACE FOR
626
MAINTENANCE
600
293
Plug cord and cord
for SC speed switch
Mounting
The Vallox TSK Multi 50/80 MC is normally installed on the
ceiling using the four mounting hooks delivered with the unit.
The weight of the unit (45 kg) must be taken into account when
mounting the unit.
Wall structure
The wall structure must be observed in the mounting.
Avoid mounting the unit on hollow, echoing intermediate
walls and on bedroom walls, or take measures to prevent
conduction of noise.
D
B
A
Water seal
Water outlet
(alternative)
SPACE FOR
MAINTENANCE
15
C
Space required
for mounting
54