Dimensioning figure and space required for installation of the Vallox Silent Klick water seal ....... . . 10 Space required by the alternative Vallox Silent Klick water seal installation method (elbow) .
INTENDED USE All Vallox ventilation units have been designed to provide appropriate and continuous ventilation so as to present no threat to health and to maintain structures in good condition. IMPORTANT In order to ensure that the indoor air presents no harm to health and remains optimal also for the structures of the building, ventilation must be kept on without disruptions.
Models Vallox 096 MV and Vallox 110 MV can be mounted either on the wall, or on the ceiling by using a mounting plate (optional). • Vallox 145 MV can be mounted either on the wall, or on the floor by using a floor rack (optional). •...
At the same time you create a MyVallox Cloud account for yourself. Read more about the service at www.myvallox.com. Ventilation unit control options. Operation of the Vallox ventilation unit can be controlled by the following means: • Through the control panel installed in the building •...
MAIN PARTS Vallox 096 MV, Vallox 110 MV, and Vallox 145 MV R model in the figure Extract air fan Post-heating radiator (behind the protective cover) (behind the extract air duct) Supply air fan Safety switch (behind the protective cover)
30 mm. Note that during mounting the unit rises 10 mm higher than the final height. Mount Vallox 096 MV, 110 MV, and Vallox 145 MV on the wall with a mounting plate, as shown in the adjacent figure. Make sure that the unit is horizontally level after mounting.
Installing the ventilation unit to the ceiling mounting plate Install the ceiling mounting plate with M8 thread bars so that it is horizontally level. NOTE The end of the thread bars must be 5 mm or less below the fastening nut. Do not fasten the ceiling mounting plate too tight to the ceiling.
MOUNTING ON A BASE NOTE Vallox 145 MV must always be installed on a base on the floor, or on the wall using a mounting plate. The base is optional. Adjust the base with adjusting legs to level it. Remove the (4 pcs) rubber plugs at the bottom of the unit.
Vallox 110 MV Main parts Dimensions and duct outlets Dimensions R model in the figure. In the L model, the parts are mirrored 1. Extract air fan 6. Supply air filter G4 (behind the protective cover) 7. Extract air filter G4 2.
To replace the filters: Disconnect the ventilation unit from the mains electricity supply. 2. Lift the latch to open the door of the Vallox ventilation unit. 3. Lift the door off. CAUTION The door is heavy.
To check and clean the heat recovery cell: Disconnect the ventilation unit from the mains electricity supply. 2. Open the Vallox ventilation unit door by first lifting the latch fully up and then lowering it back a little way. 3. Lift the door off.
Disconnect the ventilation unit from the mains electricity fan blade balancing weights. supply. 2. Lift the latch to open the door of the Vallox ventilation unit. 3. Lift the door off. CAUTION The door is heavy. 4. Remove the extract air filter (C), the cell top bracket (E) and the heat recovery cell (D).
Cleaning the extract air fan To clean the extract air fan, proceed as follows: Disconnect the ventilation unit from the mains electricity supply. 2. Lift the latch to open the door of the Vallox ventilation unit. 3. Lift the door off. CAUTION The door is heavy.
EXTERNAL ELECTRICAL CONNECTION 7028350 2014-08-29 JS MyVallox Control MyVallox REMOTE 0.3W MONITORING transmitter Modbus RTU 2x2x0,5+0,5 2x2x0,5+0,5 MyVallox MyVallox 2x2x0,5+0,5 Control transmitter 1.2W 2x2x0,5+0,5 2x2x0,5+0,5 External temperature Analog input sensor two different 2x0,5 2x0,5 NTC 4K7 functions 2x0,5 2x0,5 2x0,5 Potential-free contact data 24VDC can be programmed to display...
NOTE: COOLING ventilation unit. In this case, the pump and the solenoid valve can be controlled using a Vallox MV ventilation unit, The value set for the and no separate thermostats are needed.
EXPLODED VIEW AND PARTS LIST Vallox 096 MV NO. PART CODE PART CODE PART CODE Post-heating resistor Supply / extract air fan 1108800 Bypass flap assembly 900W (R and L 942210 (with a hood) models) 935365 R model 3491200 Door...
Vallox 145 MV NO. PART CODE NO. PART CODE NO. PART CODE Supply / extract air Post-heating resistor 1109200 Bypass flap assembly fan (with a hood) 900W 935285 R model 3475900 R model 942211 Wall mounting 3482100 L model 3475901...