Thermal Network Positioning System·Quick Start Guide
3 Installing the Positioning System
3.1 Monitoring Distance Range
Electric lens is adopted for the thermal channel of positioning system. It supports
auto-focus function and remote focus function. For different lens focal length, the
monitoring range is shown in the table below:
Table 3-1 Monitoring Range (Pixel Interval: 17um)
Lens Focal Length/mm
MRAD
Detection Range
(Vehicle)/m
Detection Range
(Human)/m
Recognition Range
(Vehicle)/m
Recognition Range
(Human)/m
Identification Range
(Vehicle)/m
Identification Range
(Human)/m
Table 3-2 Monitoring Range (Pixel Interval: 25um)
Lens Focal Length/mm
MRAD
Detection Range
(Vehicle)/m
Detection Range
(Human)/m
Recognition Range
(Vehicle)/m
Recognition Range
(Human)/m
25
50
0.68
0.34
2255
4510
735
1471
564
1127
184
368
282
564
92
184
25
50
1.00
0.50
1533
3067
500
1000
383
767
125
250
6
75
100
0.23
0.17
6765
9020
2206
2941
1691
2255
551
735
846
1127
276
368
75
100
0.33
0.25
4600
6133
1500
2000
1150
1533
375
500