Page 1
S450H 24V Hydraulic Swing Gate Operator UL325 - UL991 FAAC International Inc. FAAC International Inc. West Coast Operations Headquarter & East Coast Operations 357 South Acacia Avenue 5151 Sunbeam Road Unit 357 Suites 9-11 Fullerton, CA 92831 Jacksonville, FL 32257 Tel.
Read this instruction manual before you begin installing the product. = Information regarding personal safety and proper maintanence of the product. FAAC Model S450H - Rev: 01 - JAN 2012 FA A C M o d el S 4 50H 24V Hydraulic Swing Gate Operator...
• Install devices such as reversing edges and photo • Use only FAAC MSE MO, CN60 or M60 edge beams to provide better protection for personal sensors. property and pedestrians. Install reversing devices that are appropriate to the gate design and application.
Installing the Warning Signs This FAAC swing gate operator is supplied with two warning signs to alert people that a possible hazard exists and that appropriate actions should be taken to avoid the hazard or to reduce exposure to it.
DIMENSIONS 1. DESCRIPTION AND TECHNICAL SPECIFICATIONS The FAAC S450H automated system for swing-leaf gates con- sists of an electrical pump and an hydraulic piston transmitting the leaf movement, assembled in a single block. The model with hydraulic locking does not require the instal- 4¾...
- If the gate structure does not allow the stable fixing of the front fitting, create a firm bearing surface in the leaf structure. - It is advisable to grease all fixing pins - Opening and closing stops must always be installed - Pay special attention not to damage the operator rod.
Page 8
3.1.2 APPLICATION WITH BRACKET FASTENED TO SIDE WALL ATTENTION: do not cut the rear bracket for any reason. Refer to Figures 4 1 and 5 1 and Table 2 to determine the installation position of the operator. 3⅜ Dimensions in Inches Fig.5 1 Fig.4 1 Dimensions in Inches...
INSTALLING THE OPERATOR Install the encoder on the rear bracket by correctly engaging it on the pin, then fix it with the screw and nut Check the perfect level then weld the rear fitting to the pil- supplied (Fig. 8 Ref. a, b and c). lar or fix it by means of suitable screws, dowels / thread- ed inserts.
Page 10
15. Secure the operator to the front bracket (Fig. 15). 16. Remove the bleed screw (Fig.16 Ref. a) paying special attention to leave the sealing O-Ring in its seat. If an external mechanical 17. Install the metallic protection cover as shown in Fig. 16, stop at close is present, insert and tighten both tie-rods.
MANUAL OPERATION If the gate is to be operated manually because of a power failure or an automated system fault, activate the release device. Lift the protection lid (Fig. 18, Ref. a) and insert the key in the lock (Fig. 18, Ref. b). Turn the key 90°...
Page 12
Fig. 19 LEAF 1* LEAF 2 DL 1 DL 1 THROUGH THE BRACKET COVER OF LEAF THROUGH THE BRACKET COVER OF LEAF DL 2 DL 2 2, VERIFY THAT THE LED DL1 IS ON WHEN 1, VERIFY THAT THE LEDS DL1 AND DL2 DL 3 DL 3 THE MOTOR IS NOT IN OPERATION...
BLEEDING Loosen the tie-rods (Fig. 23 ref. a) and remove the metal protective housing (Fig. 23 ref. b). Remove the upper tie-rod and be careful with the O-ring that must remain it its seat. Fig.23 Remove the screw in Fig. 24 ref.d from the front fitting Remove the joint (Fig.24 ref.f) from the operator stem.
63001885 S450H SKINPACK 63001975 SPACERS KIT FOR S450H 63000606 SEAL KIT S450H 63001985 RELEASE ASSY S450H 714017 HYDRAULIC OIL FAAC HP 63001875 S450H ENCODER OIL LT. 1 63001965 S450H SHORT PIN 63001895 S450H CARTER WITH FAAC 63001915 REAR BRACKET FOR...
Page 15
63000676 S450H CB GEAR FLANGE 903122 ETICH.PET+TRANSPARENT 7090010015 SEAL OR 4.48X1.78 (2018) ARGENTO 45X75 63000756 S450H PLUG SEAL 63001865 FAAC STICKER FOR S450H 63000766 DIN 908 M8X1 PLUG 63000736 S450H TANK 63001985 REALEASE ASSY S450H 63000726 RETRACT TUBE S450H 63000746...
Page 16
FAAC S450H Hydraulic Operator Diagram 3: Distribution Flange Part Part Description Part Part Description Number Number 63000816 VALVE RING NUT 4180315 593-595 COMMUTATING PISTON 63000816 VALVE RING NUT 7090010015 SEAL OR 4.48X1.78 (2018) 7090050015 GASKET OR 10.82X1.78 (2043) 63000676 S450H CB GEAR FLANGE...
Page 17
FAAC S450H Hydraulic Operator Diagram 4: Emergency Lock Release Part Part Description Number 63001985 RELEASE ASSY S450H 7290445 2005 RELEASE HAND GRIP 7090895 21X2 N70B200V SEAL 7131005 KEY MOD. 3889.0913 7275275 CAP FOR LOCK 400/422 RELEASE 2005 63000666 S450H RELEASE PIN...
Page 18
E024U CONTROL BOARD DESCRIPTION & CHARACTERISTICS SETTING DL14 DL15 DL16 DL17 DL18 DL19 DL20 DL21 DL22 Fig. A1 1.1 TECHNICAL SPECIFICATIONS 1.2 LAYOUT AND COMPONENTS Main power supply RADIO 115/230 V~ 50/60 Hz switchable Connector for the radio receiver Secondary power BATTERY 24 Vdc - 16 A max.
Page 19
INPUT / OUTPUT DESCRIPTION B STP CL OP OPEN Fig. A2 LABEL FUNCTION 2 EASY 2 EASY Input for bus 2easy accessories (encoder) OPEN A N.O. Contact for total opening command OPEN B / OPEN B: N.O. Contact for opening of leaf 1 only CLOSE (with only one leaf the opening stops at 50% of traveling) CLOSE (LOGIC B-C): N.O.
Page 20
PHOTOCELLS CONNECTIONS Ho to connect Normally Close contacts. Ho to connect Normally Open contacts. (Connect them in series) (Connect them in parallel) Fig. A4 Fig. A3 The E024U board allows the connection of several safety devices (for example photocells). With photocells you can activate the FAILSAFE function, which, before each movement of the ope- rator, tests each fotocells.
Page 21
Connection of two pairs of closing photocells STP CL OP Other optional safety devices to connect in series RX= Photocell Receiver TX= Ptotocell Transmitter CL= Closing OP= Opening To use the FAIL-SAFE mode connect the negative power supply of the transmitters to OUT (pin 9), and set dip-switch 11 and 12 to ON on DS1 When using the FAIL-SAFE mode also the safety inputs not used (FSW CL , FSW OP) must be connected Fig.
Page 22
Connection of a pair of closing photocells and a pair of opening photocells STP CL OP RX= Photocell Receiver TX= Ptotocell Transmitter CL= Closing OP= Opening To use the FAIL-SAFE mode connect the negative power supply of the transmitters to OUT (pin 9), and set dip- switch 11 and 12 to ON on DS1 Fig.
Page 23
PROGRAMMING 4.1 DIP SWITCH DS1 SETTINGS FOR OPERATING LOGIC OPERATING LOGIC DS 1: SW 1 - SW 2 - SW 3 PAUSE LOGIC DESCRIPTION TIME E (default) One command opens, the next one closes. A command du- OFF OFF OFF ring opening stops the gate Semiautomatic 0 - 4...
Page 24
4.2 ADJUSTING TRIMMERS – FORCE ADJUSTMENT MOTOR 1 Turn clockwise to increase the opening and closing force TR 2 – FORCE ADJUSTEMENT MOTOR 2 Turn clockwise to increase the opening and closing force TR 3 – SPEED ADJUSTMENT FOR MOTOR1 AND MOTOR 2 Turn clockwise to increase the opening and closing speed TR 4 –...
Page 25
4.3 DIP SWITCH DS1 SETTINGS FOR BOARD SETUP BOARD SETUP DS 1: SW 4 to SW 12 The opening of leaf 2 is delayed after the opening of leaf 1. This is to avoid OPENING DELAY SW 4 that the gate’s leafs interfere with each other during the initial part of the 0 sec (default) movement.
Page 26
Active only for 3 sec. after an open impulse (from gate closed) S418 OFF OFF Active always except 3 sec. before an opening 412, 413, 415, 390, 770 OFF OFF NON FAAC LED DIAGNOSTICS SETTING DEVICE DL14 DL15 DL16 DL17 DL18 DL19 DL20 DL21...
Page 27
LED STATUS In BOLD the normal state with gate closed and working DESCRIPTION ON STEADY BLINKING Board working on AC Board working on LED BATTERY power battery power or ext Battery charging supply LED +24 Main power present Main power OFF SLOW BLINK (1 sec.
Page 28
The diagnostic LED shows only one error condition at a time, with the priority of the below table. In case there is more than one error once one is eliminated the LED will show the next LED ERROR DISPLAY NUMBER OF ERROR CONDITION SOLUTION FLASHES...
Page 29
AC connection At the point where you want the slowdown to start give an Power outlet OPEN A command with the push button or the remote that Power Supply is already stored in memory. Leaf 2 starts to slow down and and switch stops when it reaches the mechanical stop or FCA2.
Page 30
The E024U board is powered by a high efficiency switching power supply that takes 115V or 230V in input and provides 36VDC to power the board. The power supply is preset for 115V at the fac- tory, consult with FAAC Tecnical Support for 230V wiring options. 115V 230V...
Page 31
10. FIRMWARE UPGRADE For the upgrade you need a USB Flash Drive, where you have to copy the file supplied by FAAC. Then follow these steps: The E024U board keeps the operating firmware in a field pro- grammable memory, it can be easily upgraded through the on Disconnect the batteries if they are present.
Page 32
LOGIC “S” PULSES SYSTEM STATUS OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP opens released no effect no effect opens and closes no effect CLOSED leaf and closes no effect (OPEN disa- (OPEN disa- no effect after pause time (OPEN disabled) after pause time...
Page 33
LOGIC “SP” PULSES SYSTEM STATUS OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP opens and clo- opens leaf 1 and no effect no effect no effect CLOSED ses after pause closes after pause no effect (OPEN disa- no effect (OPEN disa- (OPEN disabled)
Page 34
FAAC S.p.A. intended provided it has been properly installed or FAAC International, Inc. The warranty herein and operated.
Need help?
Do you have a question about the S450 and is the answer not in the manual?
Questions and answers