Wiring / Owner's
Manual
Use this manual for circuit board 4302-018 Revision A or higher.
Entrapment Protection must be provided for the gate system where the risk of entrapment or obstruction exists. The operator
will NOT run without one or more monitored type B1 or B2 entrapment protection devices in EACH entrapment area.
UL 325 August 2018 Standard
6 4
0 0
Please refer to YOUR CHOSEN
"Gate Operator Mounting and
4302 Control Box Options" manual:
6004 swing gate operator manual - 6004-065
6006 swing gate operator manual - 6006-065
6400 swing gate operator manual - 6400-065
THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE/DOOR SYSTEMS TECHNICIAN ONLY.
Visit www.doorking.com/dealer-locator to find a professional installing and servicing dealer in your area.
Date Installed:
Installer/Company Name:
Phone Number:
Leave manual with owner : Property owner checklist in back of manual for new installation verification
Conforms To UL STD 325
Certified To CSA STD C22.2 # 247
1
4302 Solar Control Box for
4302 Solar Control Box for
4302 Solar Control Box for
2 4
V o
l t 1
S o
l a r
0 W
S o
P a
a t t
l d
n e
S e
p a
l
r a t
e l y
6 0
0 6
Copyright 2021 DoorKing
6004, 6006 and 6400 gate operators
2 4
V o
l t 2
S o
l a r
0 W
S o
P a
a t t
l d
n e
S e
p a
l
r a t
e l y
D
O
O
R
K
I
N
G
6 0
0 4
Circuit Board
Serial Number
and Revision Letter:
®
, Inc. All rights reserved.
4302-067-G-2-21
4 3
0 2
S o
C o
l a r
n t r
o l
B o
x
D o
R e
o r K
t r o
i n g
- R e
8 0
f l e
8 0
c t i v
- 0 5
I n c
e P
l u d
h o
e d
Copyright 2009 DoorKing, Inc. All rights reserved.
7
t o c
e l l
4302-067-G-2-21

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4302 and is the answer not in the manual?

Questions and answers

Susie Holton
April 30, 2025

RE: DoorKing Residential Gate Model 4302-311 quit working - Contracted with Automated Gate Services and the tech reset it, replaced 2 back-up batteries, made adjustments on the arm. It will work a few times open and close, but then quits working at random. I can reset it on the computer board - sometimes it works and sometimes it doesn't. The tech has "serviced" the gate over 10 times and $500 to no avail! He has given up! Please help!

1 comments:
Mr. Anderson
May 16, 2025

Common troubleshooting steps for a DoorKing Residential Gate Model 4302-311 that intermittently stops working after being serviced include:

1. Check Keying Devices: Disconnect keying devices one at a time to see if the LED goes off. This helps identify if a device is causing the issue.

2. Inspect External Entrapment Devices: Look for shorts or malfunctions in external entrapment protection devices.

3. Test Loop Detectors: Pull loop detector circuit boards from the loop ports. If the issue continues, the problem is not with the loop system.

4. Check Control Wires: Ensure there are no shorted or open wires from keying devices to the gate operator.

5. Bypass Keying Device: Momentarily jumper terminals 1 and 2 on the control board. If the gate operates, the keying device may be faulty.

6. Inspect for Obstructions: Make sure there are no obstructions along the gate path that could trigger the entrapment sensing system.

7. Check for Hard Shutdown: If the alarm is sounding or chirping every 5 seconds, reset the operator using the reset button or by turning the power off and on.

8. Check Gate and Hardware: Inspect for malfunctions before returning the gate to service.

This answer is automatically generated

Summary of Contents for DoorKing 4302

  • Page 1 THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE/DOOR SYSTEMS TECHNICIAN ONLY. - R e Visit www.doorking.com/dealer-locator to find a professional installing and servicing dealer in your area. f l e c t i v...
  • Page 2: Quick Guide: Dip Switches

    SW 2 - Bottom 4 Switches Relay 1 and 2 Circuit board relay activates when gate is NOT closed. 1-OFF 2-ON Operation Leave in the OFF position. Not Used Spare Leave in the OFF position. Quick Guide - 1 4302-067-G-2-21...
  • Page 3: Quick Guide: Terminals Wiring

    ANY access control device used needs a relay contact time of AT LEAST 1 SECOND to bring the circuit board out of “idle time” and operate gate. Key Switch DoorKing 8080-057 (Dry contact) Retro-Reflective Photocell...
  • Page 4: Solar Control Box Specifications

    P/N 2000-076 DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons of any such revisions or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to this manual. This manual is copyrighted, all rights reserved.
  • Page 5: Table Of Contents

    SECTION 1 - SOLAR PANEL INSTALLATION CONSIDERATIONS Solar Panel Concerns BEFORE Installation Solar Panel Positioning SECTION 2 - WIRING Control Box Overview Wiring Operators to 4302 Circuit Board Entrapment Protection Wiring 12-14 Full Open & Circuit Board Terminals Wiring DKS Plug-In Loop Detector (Reverse Loops ONLY)
  • Page 6: Swing Gate Requirements

    If bottom of gate is 4” to 16”above the ground at any part of the gate’s traveling path, entrapment protection is REQUIRED for this area. Not Allowed 4 inches to 16 inches Gates shall have smooth bottom edges, with vertical bottom edged protrusions NOT exceeding 0.50 inches. 4302-067-G-2-21...
  • Page 7 The operator will NOT run without one or more property. monitored type B1 or B2 entrapment protection devices in EACH ENTRAPMENT AREA. 4302-067-G-2-21...
  • Page 8: Astm F2200 Standard For Gate Construction

    6. One or more contact sensors shall be located at the bottom edge of a vertical barrier (arm). • Be sure you have instructed the owner of the gate operator about safe and proper operation and testing of the gate operator. 4302-067-G-2-21...
  • Page 9: Important Notices

    Do not allow children to play in the area of the operator or to play with any gate-operating device. • To remove the gate operator from service, operate the gate to the full open position and then shut off power to the operator at the service panel. 4302-067-G-2-21...
  • Page 10: Ul 325 Entrapment Protection

    Type C - Inherent force limiting, inherent adjustable clutch or inherent pressure relief device. Type D - Actuating device requiring constant pressure to maintain opening or closing motion of the gate. * B1 and B2 means of entrapment protection must be MONITORED. 4302-067-G-2-21...
  • Page 11: Glossary

    ENTRAPMENT - The condition when an object is caught or held in a position that increases the risk of injury. 4302-067-G-2-21...
  • Page 12: Section 1 - Solar Panel Installation Considerations

    Solar Control Box Requirements: • (1) ONE 24 Volt 10 Watt Solar Panel (P/N 2000-077) for 18 Amp/Hr Batteries. • (1) ONE 24 Volt 20 Watt Solar Panel (P/N 2000-076) for 35 Amp/Hr Batteries. 4302-067-G-2-21...
  • Page 13: Solar Panel Positioning

    (At the beginning of summer and winter). Add approximately 6° in the summer and subtract approximately 6° in the winter from your “general” tilt angle on this chart. Your tilt angle may vary from this. 75° 50° 35° 4302-067-G-2-21...
  • Page 14: Section 2 - Wiring

    See page 11. Power FULL Terminal OPEN See page 19. 4302-018 PUSH TO OPERATE PUSH technician use only Circuit Board Terminal 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Power Switch See page 19.
  • Page 15: Wiring Operators To 4302 Circuit Board

    2.2 Wiring Operators to 4302 Circuit Board IMPORTANT: External entrapment protection MUST be installed or the operator will NOT function. See next page. Open Beam Close 1476-010 Beam FIRE Secondary Operator ONLY DO NOT connect primary/single operator to this terminal.
  • Page 16: Entrapment Protection Wiring

    B2 entrapment protection required by UL 325 standards. Install these devices where the risk of entrapment or a safety hazard exists. Installations can vary. ONE DoorKing 8080-057 photocell included, see next page. Entrapment Protection must be provided for the gate system where the risk of entrapment or obstruction exists. The operator will NOT run without ONE or more monitored type B1 or B2 external entrapment protection devices installed in each entrapment area.
  • Page 17 2.3 Entrapment Protection Continued DoorKing 8080-057 Retro-Reflective Photocell Type B-1 This retro-reflective photocell (UL 325 Type B-1) complies with the 2018 UL 325 standards. It must be wired to the control box using the photocell’s NORMALLY OPEN input so the control box can monitor the photocell. The photocell is powered by 24 VAC from the #3 circuit board terminal if desired.
  • Page 18 HARDWIRED Multiple Reversing Edge Configuration ONLY 2-Wire End-of-Line Edge FULL OPEN 4302-018 4-Wire 4-Wire In-Line Edge In-Line Edge 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20...
  • Page 19: Full Open & Circuit Board Terminals Wiring

    ANY access control device used needs a relay contact time of AT LEAST 1 SECOND to bring the circuit board out of “idle time” and operate gate. Key Switch DoorKing 8080-057 (Dry contact) Retro-Reflective Photocell...
  • Page 20: Dks Plug-In Loop Detector (Reverse Loops Only)

    A loop detection system will sense a vehicle like a metal detector and send a signal to the gate operator preventing the gate from automatically opening or closing on a vehicle when it is in the gate’s path. DoorKing recom- mends that a licensed installer perform this work.
  • Page 21: External Loop Detector Wiring

    A loop detection system will sense a vehicle like a metal detector and send a signal to the gate operator preventing the gate from automatically opening or closing on a vehicle when it is in the gate’s path. DoorKing recommends that a licensed installer perform this work.
  • Page 22: Battery Wiring

    Battery Replacement Note: DoorKing HIGHLY e r ! Battery Wiring Notes: recommends replacing the batteries every two years Use ONLY 12 Volt batteries. because of normal battery deterioration.
  • Page 23: Solar Panel Wiring

    Solar NEG White wire to Solar Pos (Hot). DO NOT Connect a Black wire to Solar Neg (Neutral). Plug-In Transformer to the Power Terminals 4302-018 PUSH TO OPERATE PUSH technician use only Circuit Board Terminal To Test Operator: 2 3 4 5 6 7 8...
  • Page 24: Section 3 - Adjustments

    The switch settings and adjustments in this section should be made after your installation and wiring to the operator(s) is complete. Whenever any programming or switch setting on the control board are changed, press the reset button for new settings to take effect. 3.1 4302 Circuit Board Description and Adjustments “Optional” External Loop Detectors See 15 and 17.
  • Page 25: Dip-Switches

    SECONDARY • Switch 2 will be the OPPOSITE setting as switch 1 for the 6004 and 6400. Operator Note: SW 1, switch 7 MUST also be ON when using a secondary operator. SW 1 Switches continued on next page 4302-067-G-2-21...
  • Page 26 Switch 1 MUST be OFF and Switch 2 MUST be ON. DO NOT use any other switch combinations. SW 2-Switch 3: Not used, leave in the OFF position. SW 2-Switch 4: Spare switch. Leave in OFF position. 4302-067-G-2-21...
  • Page 27: Limit Sensors Adjustment - Select Your Specific Operator

    2 controls secondary operator opening on DIP-switch SW 1, switch 1 direction. DIP-switch SW 1, switch 7 MUST be and 2 settings (See page 19) Single or Dual Operators ON when using dual operators. (See page 20) SW 1 4302-067-G-2-21...
  • Page 28: 6006 Limit Sensors Only

    IMPORTANT: The operator MUST OPEN GATE upon initial power up and OPEN command. If the operator closes gate after giving first open command, shut off power and reverse DIP-switch SW1, switch 1 setting otherwise operator will NOT function correctly. 4302-067-G-2-21...
  • Page 29: 6400 Limit Sensors Only

    Open or Close limits depending opening direction. DIP-switch SW 1, switch 7 on DIP-switch SW 1, switch 1 MUST be ON when using dual operators. Single or Dual Operators and 2 settings. (See page 21) (See page 21) SW 1 4302-067-G-2-21...
  • Page 30: Inherent Reverse Sensor Adjustment

    Place an immobile object along the gate path, allowing the gate to strike it while in the open or close cycle. The gate must reverse direction after striking the object. If it does not, increase the reverse sensitivity (steps ) and repeat this test until the correct sensitivity has been set for the OPEN and CLOSE directions. 4302-067-G-2-21...
  • Page 31: Optional" Radio Receiver Model (8040-080)

    3.5 “Optional” Radio Receiver Model (8040-080) ® ® The 8040-080 receiver operates at 318 MHz and MUST be used with either the DoorKing MicroPlus OR MicroClik transmitters (Sold Separately). ® MicroPlus Transmitters (Sold Separately) Over 286,000,000 transmitter codes available plus an encrypted sync code (often called a “rolling code”) that changes every time the ®...
  • Page 32 3. The receiver will then emit a long flash and long beep indicating ALL memory, including master transmitters have been erased from memory. Note: If receiver does not emit a continuous beep after pressing the button 3 times, try repeating step 2 faster or slower until it does. Continued on next page. 4302-067-G-2-21...
  • Page 33: Shutdown Conditions

    3.5 Radio Receiver Continued Set to LOW - Power Mode The receiver can be changed from normal-power to LOW-Power mode. LOW-power mode is used in DoorKing solar gate operator applica- tions. Wiegand output will NOT work in LOW-Power mode. 1. Turn the Programming Selector to “Position 8”.
  • Page 34: Hard Shutdown (Alarm Activated)

    OR power is shut-off to operator. Reset Button Shutting OFF Alarm DoorKing operators have a built-in alarm Open reset push button on the circuit board.
  • Page 35: Section 4 - Maintenance And Troubleshooting

    Pull the loop detector circuit boards from the loop ports on the operator circuit board. If the malfunction persists, the problem is not with the loop system. For more information refer to the loop detector instruction sheet and the DoorKing Loop and Loop Detector Information Manual.
  • Page 36: Troubleshooting

    Gate opens a short • Check the secondary safety devices. distance, then stops • Disconnect the gate from the gate operator and check that the gate swings freely without any and reverses. binding. • Continue troubleshooting or replace the circuit board. 4302-067-G-2-21...
  • Page 37 Hard Shutdown Section 3.5, page 27. seconds. Operator will not run. Operator has intermittent • The 24 V POS terminal 250 mA power has been exceeded. functionality Check total amp draw of connected device(s). problems that vary. 4302-067-G-2-21...
  • Page 38: Accessory Items

    DKS 8040 Low Current Draw Radio Receiver and Antenna - Operates at ® 318 MHz and MUST be used with either the DoorKing MicroPlus ® MicroClik transmitters. P/N 8040-080 o l e...
  • Page 39: Solar Control Box Schematics

    Black 24 V NEG 24 V POS FULL Solar POS OPEN Solar NEG 4302-018 Power Terminal 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Circuit Board Terminal Black Wire Harness...
  • Page 40: Important Information For Owner

    24 V NEG 24 V POS Solar POS Solar NEG FULL OPEN 4302-018 PUSH TO OPERATE PUSH technician use only Turn OFF power 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 switch to shut-off power to operator.
  • Page 41: Manually Operating The Gate - No Power

    (See previous page). l o c Insert release tool and turn Release to release the arm. Push or Tool pull the gate, NOT the n d l operator arm. Insert key and turn to release handle. 4302-067-G-2-21...
  • Page 42: Gate Operator's Monthly Checkup

    If you feel uncomfortable performing any of these inspections or testing, a qualified service technician will perform the visual inspections and testing for you. You can find a trained service technician at DoorKing’s “Dealer Locator” at www.doorking.com Visual Inspection Visually inspect the rollers, fasteners, brackets and other gate hardware for proper alignment, proper tightness, and signs of damage, breakage, looseness, rust or wear.
  • Page 43: New Installation Checklist For Installer And Property Owner

    The installer has explained to the property owner that a regular maintenance schedule for both the gate and the gate operator is recommended, including regular testing of entrapment protection as outlined in the manufacturer's instructions. The installer has left the installation/owners manual with the property owner for future reference. 4302-067-G-2-21...
  • Page 44 NOT run without one or more monitored type B1 or B2 entrapment protection devices in EACH entrapment area. UL 325 August 2018 Standard THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE/DOOR SYSTEMS TECHNICIAN ONLY. Visit www.doorking.com/dealer-locator to find a professional installing and servicing dealer in your area. www.doorking.com DoorKing, Inc.