Operating Modes
Frame Relay, multilink Frame Relay
PPP, MLPPP
HDLC
T1/FT1 Interface
Supported Standards: AT&T TR 62411,
AT&T TR 65016, ANSI T1.403, 
Bellcore TR 194
Line Rate: 1.544 Mbps +75 bps
Line Code: AMI or B8ZS
Framing: D4 (SF) or ESF
FT1 Line Rate: DS0 channelized (multiples
of 64 kbps)
Input Signal: 0 to -36 dB (DS1)
Line Build Out: 0, -7.5, -15, -22.5 dB
(long), 0 to 655 ft. (short)
DS0 Assignment: Programmable
Connector: RJ-48C
Clock Source
Network
Internal
44
Figure
18) provides a T1 (full or fractional) WAN interface
WAN-T1

Figure 18. NetVanta T1/FT1 NEBS NIM

Features and Specifications
Copyright © 2019 ADTRAN, Inc.
NetVanta 3200/3300/3400 Series
Diagnostics
Test Pattern Generation and Detection:
15
QRSS, 511, 2
- 1, 2
all zeros
Network loopbacks (local and remote);
responds to inband and FDL loop codes
Alarm generation and detection
Network and user sets of performance data
(15 minutes and 24 hours)
Compliance
FCC Part 15 Class A
EN 55022 Class A
EN 55024
UL/CUL 60950-1
NEBS Level 3
GR-63-CORE
GR-1089-CORE
7
Environmental
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent 
noncondensing
Physical
Dimensions: 2.75-inch W x 4.25-inch D
20
- 1, all ones, 
61200860L1-34AE