Page 1
PSS u2 ES 16DI Control system PSS u2 Remote I/O system PSS u2 Operating Manual-1004551-EN-03...
Page 2
We do assure you that all persons are regarded without discrim- ination and on an equal basis. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
This describes a situation in which the product or devices could be dam- aged and also provides information on preventive measures that can be taken. It also highlights areas within the text that are of particular import- ance. Operating Manual PSS u2 ES 16DI 1004551-EN-03...
Page 5
Introduction INFORMATION This gives advice on applications and provides information on special fea- tures. Operating Manual PSS u2 ES 16DI 1004551-EN-03...
The module PSS u2 ES 16DIs may be used in conjunction with the following terminal block: 16-pin terminal block System requirements INFORMATION The module is supported by PASconfig from version 2.0.0 – We recommend that you always use the latest version (download from www.pilz.com). Operating Manual PSS u2 ES 16DI 1004551-EN-03...
Any type of modification has been made (e.g. exchanging components on the PCB boards, soldering work etc.). 3.3.3 Disposal When decommissioning, please comply with local regulations regarding the disposal of electronic devices (e.g. Electrical and Electronic Equipment Act). Operating Manual PSS u2 ES 16DI 1004551-EN-03...
(ST) Periphery Supply +24 V DC Fig.: Block diagram PSS u2 ES 16DI Supply The module is supplied with voltage via the head module. Inputs The status of the inputs is signalled to the head module via the module bus.
Page 10
0-signal at the terminal 1-signal at the terminal after pulse stretching has after pulse stretching has starts pulse stretching elapsed elapsed Waiting for 0-signal 1-signal in the module Fig.: States for pulse stretching Operating Manual PSS u2 ES 16DI | 10 1004551-EN-03...
Page 11
Fig.: Timing diagram: pulse stretching ≤ signal duration of 1-signal Legend Clamp Signal at the terminal Pulse stretching Pulse stretching Stretched signal Stretched signal Duration of 1-signal 1-signal Duration of pulse stretching stretch Operating Manual PSS u2 ES 16DI | 11 1004551-EN-03...
Page 12
Time for which a signal must be present at the input in order to be de- signal_min tected Stretched 1-signal in the module TRUE Stretched 0-signal in the module FALSE Grey shaded Signals that are not detected during stretching area Operating Manual PSS u2 ES 16DI | 12 1004551-EN-03...
– Switching off the LEDs to display the module and terminal status Standby mode – All module functions are inactive. – The LEDs for displaying the module and terminal status are switched off. Operating Manual PSS u2 ES 16DI | 13 1004551-EN-03...
1: "1"-signal (+ 24 V) at the input Bit 1 Input data I1 Bit 2 Input data I2 Bit 3 Input data I3 Bit 4 Input data I4 Bit 14 Input data I14 Bit 15 Input data I15 Operating Manual PSS u2 ES 16DI | 14 1004551-EN-03...
6.1.1 Dimensions The dimensions include the backplane, electronic module and terminal block. 12,5 51,1 111,1 Fig.: Dimensions in mm, including backplane, electronic module and terminal block Operating Manual PSS u2 ES 16DI | 15 1004551-EN-03...
Inserting an electronic module 1. Insert the electronic module into the suspen- sion lug on the back- plane. 2. Swivel the electronic module downwards until you hear it click into place. Operating Manual PSS u2 ES 16DI | 16 1004551-EN-03...
Page 17
Installation 3. Insert the terminal block into the suspen- sion lug on the module. 4. Swivel the terminal block upwards until you hear it click into place. Operating Manual PSS u2 ES 16DI | 17 1004551-EN-03...
2. Press the unlocking mechanism that is shown by the arrow and pull off the electronic module upwards. Operating Manual PSS u2 ES 16DI | 18 1004551-EN-03...
– Restart of the head module. After a restart, the system behaves as after a warm reset using a reset pushbutton (see operating manual of the head module, chapter “Reset pusbutton", section "Carrying out a warm reset (restart)"). Operating Manual PSS u2 ES 16DI | 19 1004551-EN-03...
The error will be signalled to the head module and will be entered in the head module's diagnostic log. Display elements and messages Legend [1] Module status display [2] Terminal status display Operating Manual PSS u2 ES 16DI | 21 1004551-EN-03...
Page 22
After the "too hot" message has been received, if the temperature drops back below the "too warm" threshold value, the module will switch to an error-free state. Legend LED on LED flashes LED flashes briefly LED off Operating Manual PSS u2 ES 16DI | 22 1004551-EN-03...
In accordance with the standard EN 60068-2-78 Humidity 93 % r. h. at 40 °C Condensation during operation Not permitted Max. operating height above sea level 2000 m EN 61131-2 (Zone B) Operating Manual PSS u2 ES 16DI | 23 1004551-EN-03...
Page 24
2500 V Mechanical data Material Housing Mounting type plug-in Dimensions Height 110,8 mm Width 12,5 mm Depth 72,5 mm Weight 35 g Where standards are undated, the 2017-05 latest editions shall apply. Operating Manual PSS u2 ES 16DI | 24 1004551-EN-03...
Label holder for terminal block 328912 (10 pcs.) 61 x 11.5 mm, scope of supply: 10 pieces Codierelemente Produkttyp Merkmale Bestell-Nr. PSS u2 A CE E (10 pc.) Codierelemente für Elektronikmodule, 10 328860 Stück Operating Manual PSS u2 ES 16DI | 25 1004551-EN-03...
Page 26
Order reference Backplanes Product type Features Order no. PSS u2 B 1 Backplane, 1 slot 328811 PSS u2 B 4 Backplane, 4 slots 328810 Operating Manual PSS u2 ES 16DI | 26 1004551-EN-03...
Page 27
We are represented internationally. Please refer to our homepage www.pilz.com for further details or contact our headquarters. Headquarters: Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com, Internet: www.pilz.com...
Need help?
Do you have a question about the PSS u2 ES 16DI and is the answer not in the manual?
Questions and answers