Advertisement

Quick Links

PSS u2 ES 16DOD 0.5A
}
Control system PSS u2
}
Remote I/O system PSS u2
Operating Manual-1003616-EN-03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSS u2 ES 16DOD 0.5A and is the answer not in the manual?

Questions and answers

Summary of Contents for Pilz PSS u2 ES 16DOD 0.5A

  • Page 1 PSS u2 ES 16DOD 0.5A Control system PSS u2 Remote I/O system PSS u2 Operating Manual-1003616-EN-03...
  • Page 2 We do assure you that all persons are regarded without discrim- ination and on an equal basis. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
  • Page 3: Table Of Contents

    General wiring guidelines ......................7.1.1 Connection mechanism for terminal blocks ................Terminal configuration ......................Operation ..........................Display elements and messages ....................Technical details ........................Order reference ........................10.1 Product ............................. 10.2 Accessories ..........................Operating Manual PSS u2 ES 16DOD 0.5A 1003616-EN-03...
  • Page 4: Introduction

    This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product. This documentation is valid for the product PSS u2 ES 16DOD 0.5A hardware version 01 or higher. It is valid until new documentation is published.
  • Page 5 Introduction INFORMATION This gives advice on applications and provides information on special fea- tures. Operating Manual PSS u2 ES 16DOD 0.5A 1003616-EN-03...
  • Page 6: Overview

    Details of the terminal blocks that can be used are available under "Intended Use". Module features Application of the product PSS u2 ES 16DOD 0.5A: Electronic module with digital outputs and expanded diagnostics for standard applications The product has the following features: 16 Digital outputs –...
  • Page 7: Safety

    Use of the module outside the areas described in this manual, Any use of the module that is not in accordance with the technical details. The module PSS u2 ES 16DOD 0.5A may be used in conjunction with the following ter- minal block:...
  • Page 8: Safety Regulations

    Any type of modification has been made (e.g. exchanging components on the PCB boards, soldering work etc.). 3.3.3 Disposal When decommissioning, please comply with local regulations regarding the disposal of electronic devices (e.g. Electrical and Electronic Equipment Act). Operating Manual PSS u2 ES 16DOD 0.5A 1003616-EN-03...
  • Page 9: Function Description

    The value that is to be used as the substitute value can be configured. Substitute values may be: Output switched off (default value) Output switched on Last valid value Operating Manual PSS u2 ES 16DOD 0.5A 1003616-EN-03...
  • Page 10: Reaction Times

    – The module switches off the voltage at the digital outputs. Standby mode – All module functions are inactive. – The LEDs for displaying the module and terminal status are switched off. Operating Manual PSS u2 ES 16DOD 0.5A | 10 1003616-EN-03...
  • Page 11: Address Assignment

    Bit 4 Valid bit of output O4 Bit 5 Valid bit of output O5 Bit 6 Valid bit of output O6 Bit 7 Valid bit of output O7 Byte 1 Operating Manual PSS u2 ES 16DOD 0.5A | 11 1003616-EN-03...
  • Page 12 Valid bit of output O11 Bit 4 Valid bit of output O12 Bit 5 Valid bit of output O13 Bit 6 Valid bit of output O14 Bit 7 Valid bit of output O15 Operating Manual PSS u2 ES 16DOD 0.5A | 12 1003616-EN-03...
  • Page 13: Installation

    6.1.1 Dimensions The dimensions include the backplane, electronic module and terminal block. 12,5 51,1 111,1 Fig.: Dimensions in mm, including backplane, electronic module and terminal block Operating Manual PSS u2 ES 16DOD 0.5A | 13 1003616-EN-03...
  • Page 14: Inserting And Removing An Electronic Module

    Unforeseeable error reactions may be triggered if modules are inserted and removed under load. 6.2.1 Inserting an electronic module 1. Insert the electronic module into the suspen- sion lug on the back- plane. Operating Manual PSS u2 ES 16DOD 0.5A | 14 1003616-EN-03...
  • Page 15 3. Insert the terminal block into the suspen- sion lug on the module. 4. Swivel the terminal block upwards until you hear it click into place. Operating Manual PSS u2 ES 16DOD 0.5A | 15 1003616-EN-03...
  • Page 16: Removing An Electronic Module

    2. Press the unlocking mechanism that is shown by the arrow and pull off the electronic module upwards. Operating Manual PSS u2 ES 16DOD 0.5A | 16 1003616-EN-03...
  • Page 17: Changing An Electronic Module During Operation

    – Restart of the head module. After a restart, the system behaves as after a warm reset using a reset pushbutton (see operating manual of the head module, chapter “Reset pusbutton", section "Carrying out a warm reset (restart)"). Operating Manual PSS u2 ES 16DOD 0.5A | 17 1003616-EN-03...
  • Page 18: Wiring

    The minimum cable cross section for field connection terminals on the terminal blocks is 0.15 mm (AWG26). The maximum cable cross section for field connection terminals on the terminal blocks is 1.5 mm with ferrules (AWG14) Use copper wiring. Operating Manual PSS u2 ES 16DOD 0.5A | 18 1003616-EN-03...
  • Page 19: Terminal Configuration

    12: Output O11 12: 0 V 13: Output O12 13: 0 V 14: Output O13 14 0 V 15: Output O14 15: 0 V 16: Output O15 16: 0 V Operating Manual PSS u2 ES 16DOD 0.5A | 19 1003616-EN-03...
  • Page 20: Operation

    The module status display See module's dia- and the terminal status display gnostic log on the relevant output flash synchronously Short circuit/overload/under- voltage Temperature warning: Too See module's dia- warm (1) gnostic log Operating Manual PSS u2 ES 16DOD 0.5A | 20 1003616-EN-03...
  • Page 21 After the "too hot" message has been received, if the temperature drops back below the "too warm" threshold value, the module will switch to an error-free state. Legend LED on LED flashes LED flashes briefly LED off Operating Manual PSS u2 ES 16DOD 0.5A | 21 1003616-EN-03...
  • Page 22: Technical Details

    In accordance with the standard EN 60068-2-1/-2 Temperature range -40 - 70 °C Climatic suitability In accordance with the standard EN 60068-2-78 Humidity 93 % r. h. at 40 °C Operating Manual PSS u2 ES 16DOD 0.5A | 22 1003616-EN-03...
  • Page 23 Mechanical data Material Housing Mounting type plug-in Dimensions Height 110,8 mm Width 12,5 mm Depth 72,5 mm Weight 36 g Where standards are undated, the 2015-04 latest editions shall apply. Operating Manual PSS u2 ES 16DOD 0.5A | 23 1003616-EN-03...
  • Page 24: Order Reference

    Label holder for terminal block 328912 (10 pcs.) 61 x 11.5 mm, scope of supply: 10 pieces Codierelemente Produkttyp Merkmale Bestell-Nr. PSS u2 A CE E (10 pc.) Codierelemente für Elektronikmodule, 10 328860 Stück Operating Manual PSS u2 ES 16DOD 0.5A | 24 1003616-EN-03...
  • Page 25 Order reference Backplanes Product type Features Order no. PSS u2 B 1 Backplane, 1 slot 328811 PSS u2 B 4 Backplane, 4 slots 328810 Operating Manual PSS u2 ES 16DOD 0.5A | 25 1003616-EN-03...
  • Page 26 We are represented internationally. Please refer to our homepage www.pilz.com for further details or contact our headquarters. Headquarters: Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com, Internet: www.pilz.com...

Table of Contents